8. Spindle Parameters
8.4 MDS-C1-SPM
II - 285
No. Items
Details
Setting
range
Standard
setting
3321 SP121
MPCSH Orientation
deceleration
rate H
winding
compensa-
tion magnifi-
cation
Set the compensation magnification of the
orientation deceleration rate for the H winding.
Orientation deceleration rate for the H
winding
= SP006 × SP121/256
When set to "0", will become the same as
SP006.
0 to 2560
(1/256-fol
d)
0
3322 SP122
MPCSL Orientation
deceleration
rate L
winding
compensa-
tion magnifi-
cation
Set the compensation magnification of the
orientation deceleration rate for the L winding.
Orientation deceleration rate for the L
winding
= SP006 × SP122/256
When set to "0", will become the same as
SP006.
0 to 2560
(1/256-fol
d)
0
3323
to
3325
SP123
to
SP125
Use not possible.
0
0
3326 SP126 MPGH Orientation
position gain
M coil com-
pensation
Set this to set the orientation position loop
gain for the coil changeover motor to the M
coil's unique value.
0 to 2560
(1/256-
fold)
0
3327 SP127 MPCSM Orientation
deceleration
rate M coil
compensa-
tion
Set this to set the orientation deceleration rate
for the coil motor to the M coil's unique value.
0 to 2560
(1/256-
fold)
0
3328 SP128 OXKPM Position
loop gain
magnifi-
cation after
orientation
gain
change-
over (M coil)
Set the M coil gain magnification to be used
after in-position when gain changeover is
valid (SP097: SPEC0-bitC=1) during
orientation.
0 to 2560
(1/256-
fold)
0