8. Spindle Parameters
8.4 MDS-C1-SPM
II - 294
No. Items
Details
Setting
range
Standard
setting
3394
(PR)
SP194 VGTP
Synchronized
tapping
speed loop
gain
proportional
term
Set the speed loop proportional gain in
synchronized tapping mode.
0 to 2000
(1/s)
63
3395
(PR)
SP195 VGTI
Synchronized
tapping
speed loop
gain integral
term
Set the speed loop integral gain in
synchronized tapping mode.
0 to2000
(0.1 1/s)
60
3396
(PR)
SP196 VGTD
Synchronized
tapping
speed loop
gain delay
advance
term
Set the speed loop delay advance gain in
synchronized tapping mode.
When this parameter is set to "0", PI control is
applied.
0 to 1000
(0.1 1/s)
15
3397
SP197
Use not possible.
0
0
3398
(PR)
SP198 VCGT
Synchronized
tapping
target value of
variable speed
loop
proportional
gain
Set the magnification of speed loop
proportional gain with respect to SP194
(VGTP) at the maximum motor speed defined
in SP017 (TSP) in synchronized tapping mode.
0 to 100
(%)
100
3399
(PR)
SP199 VCST
Synchronized
tapping
change
starting speed
of variable
speed loop
proportional
gain
Set the speed where the speed loop
proportional gain change starts during
synchronized tapping.
SP199
SP017
SP194
SP194×
(SP198/100)
Proportional gain
Speed
0 to
32767
(r/min)
0