10. PLC Constants
10.1 PLC Timer
II - 316
10. PLC Constants
10.1 PLC Timer
(SETUP PARAM 6. 1/14) to (SETUP PARAM 6. 2/14)
#
PLC device
Item
Details
Setting range
6000
6015
T000
T015
10ms adding
timer <10ms>
Set the time for the timer used in the PLC
program (ladder).
(Note) This setting value is valid when
parameter "#6449 bit0" in the
following "[BIT SELECT]" is set to
"0".
0 to 32767 (×10ms)
6016
6095
T016
T095
100ms adding
timer <10ms>
Set the time for the timer used in the PLC
program (ladder).
(Note) This setting value is valid when
parameter "#6449 bit0" in the
following "[BIT SELECT]" is set to
"0".
0 to 32767 (×100ms)
6096
6103
T096
T103
100ms
cumulative
timer
<100ms INC>
Set the time for the timer used in the PLC
program (ladder).
(Note) This setting value is valid when
parameter "#6449 bit0" in the
following "[BIT SELECT]" is set to
"0".
0 to 32767 (×100ms)
(SETUP PARAM 6. 10/14) to (SETUP PARAM 6. 14/14)
#
PLC device
Item
Details
Setting range
6600
6999
R1200/bit0
R1250/bit0
R1224/bitF
R1274/bitF
PLC timer
expansion
10ms adding
timer
<10ms>
Set the time for the expanded PLC timer
This is set for the timer coils: R1200 to
R1224, and timer contacts: R1250 to
R1274.
A timer command can be issued to a
contact other than the existing timer
contacts (T0 to T103, Q0 to Q151).
0 to 32767 (×10ms)
10.2 PLC Counter
(SETUP PARAM 6. 3/14)
#
PLC device
Item
Details
Setting range
6200
6223
C000
C023
Counter
Set the time for the counter used in the
PLC program (ladder).
(Note) This setting value is valid when
parameter "#6449 bit1" in the
following "[BIT SELECT]" is set to
"0".
0 to 32767