13. Auxiliary Axis Parameter
II - 326
No. Name
Details
Setting
range
Default
value
7
ATU
Auto-tuning
Set the adjustment of the auto-tuning. Do not set values without a description.
0 1 0 2 (Default
setting
value)
Setting
value
Details
1
Low response (low-rigidity loads, loads
which easily vibrate)
2
Standard
setting
value
3
Standard
setting
value
4
Standard
setting
value
5
High response (high-rigidity loads, loads
which do not easily vibrate)
Setting
value
Details
0
Standard
2
Large friction amount (set the position loop
gain slightly lower)
Setting
value
Details
0
Only auto-tuning PG2, VG2, VIC, and GD2.
1
Only auto-tuning PG1, PG2, VG1, VG2,
VIC, and GD2 (total gain).
(Standard setting)
2
No
auto-tuning.
8 PG1
Position
loop
gain 1
Set the position loop gain for the model loop.
Determine the tracking ability regarding the
position commands.
4 to 1000 (1/s) 70
9
(Not
used.)
0
10 EMGt Deceleration
control time
constant
Set the deceleration time from the clamp speed
(Aspeed1). For normal rapid traverse, set the
same value as the acceleration/deceleration time
constant.
0 to 32768 (ms) 500
11
(Not
used.)
0
12
(Not
used.)
0
13 MBR
Vertical
axis
drop
prevention
time
Input the time the servo OFF is delayed during
servo OFF command. Increase the setting by
100ms at a time and set the minimum value where
the axis does not drop.
0 to 1000 (ms) 100
14 NCH
Notch
filter
No.
Set the frequency of the machine resonance suppression filter.
Do not set values without a description.
Setting
value
0 1 2 3 4 5 6 7
Frequency
(Hz)
No
start
1125
563
375
282 225 188 161
Summary of Contents for MELDAS 60 Series
Page 1: ......
Page 2: ......
Page 4: ......
Page 6: ......
Page 10: ......
Page 13: ...I EXPLANATION OF ALARMS ...
Page 14: ......
Page 95: ...II EXPLANATION OF PARAMETERS ...
Page 96: ......
Page 443: ......