13. Auxiliary Axis Parameter
II - 330
No. Name
Details
Setting
range
Default
value
102
(PR)
Cont2 Control
parameter 2
This is a HEX setting parameter. Set bits without a description to their default
values.
bit
F
E
D
C
B
A
9
8
7
6 5 4 3 2
1
0
Default
value
0
0
0
0
0
0
0
0
1
0
0
0
0
1
1
0
bit
Meaning when "0" is set
Meaning when "1" is set
0
1
Error not corrected at servo OFF
Error corrected at servo OFF
2
Linear axis
Rotation axis
3
Station assignment direction CW
Station assignment direction CCW
4
Uniform index
Non-uniform index
5
DO channel standard assignment DO channel reverse assignment
6
2-wire detector communication
4-wire detector communication
7
Incremental detection
Absolute position detection
8
9
A
B
C
D
E
F
103
(PR)
EmgCont Emergency
stop control
This is a HEX setting parameter. Set bits without a description to their default
values.
bit
F
E
D
C
B
A
9
8
7
6
5 4 3 2 1
0
Default
value
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
bit
Meaning when "0" is set
Meaning when "1" is set
0
External emergency stop valid
External emergency stop
invalid (default value)
1
Dynamic brake stop at
emergency stop
Deceleration control stop at
emergency stop
2
NC bus emergency stop input
valid
NC bus emergency stop input
invalid
3
NC bus emergency stop output
valid
NC bus emergency stop output
invalid
4
5
6
7
8
9
A
B
C
D
E
F