13. Auxiliary Axis Parameter
II - 335
< Operation parameter group 2 >
No. Name
Details
Setting
range
Default
value
158 Aspeed2
Operation
parameter
group 2
Automatic
operation
speed
Set the feedrate during automatic operation
when operation parameter group 2 is selected.
1 to 100000
(°/min or
mm/min)
5000
159 Mspeed2 Operation
parameter
group 2
Manual
operation
speed
Set the feedrate during manual operation or
JOG operation when operation parameter
group 2 is selected.
1 to 100000
(°/min or
mm/min)
2000
160 time2.1
Operation
parameter
group 2
Acceleration/
deceleration
time constant
1
Set the linear acceleration/deceleration time for
the operation parameter group 1 automatic
operation speed (clamp speed) when operation
parameter group 2 is selected. When operating
at speeds less than the clamp speed, the axis
will linearly accelerate/decelerate at the
inclination determined above.
When this is set together with
acceleration/deceleration time constant 2,
S-shape acceleration/deceleration is carried
out. In this case, set the
acceleration/deceleration time of the linear part
in this parameter.
1 to 9999 (ms) 100
161 time2.2
Operation
parameter
group 2
Acceleration/
deceleration
time constant
2
Set this parameter when carrying out S-shape
acceleration/deceleration.
When S-shape acceleration/deceleration is
carried out, set the total time of the non-linear
parts. When 1 is set in this parameter, linear
acceleration/deceleration is carried out.
In the handle feed operation mode, this set
value is regarded as the time constant for the
linear acceleration/deceleration.
1 to 9999 (ms) 1