2. Operation Messages on Setting And Display Unit
2.1 Operation Errors
I - 48
Error No.
Error message
Details
E02 DATA
OVER
∆
• The setting data exceeded the setting range.
• The compensation data specification exceeded the range when
inputting the tool offset data on tape‚ so that block could not be
input. Press the INPUT key again while the input screen is
displayed‚ and the input will continue from the next block.
• When workpiece coordinate offsets are measured, the
calculation results given by pressing the CALC key are
exceeding the specified range. Correctly specify the tool length
or the wear data of cutting edges used for the calculation.
• #1003 iunit was set to D when the least command increment
0.01µm option was not available.
• When there was no option, 2 or more was specified for #1043
lang. Otherwise, an option was added and 24 or more was
specified for #1043 lang.
E03
No. NOT FOUND
∆
• The corresponding setting No. (#) was not found. This error
occurs if a setting No. not found on the screen was set and input‚
or if a variable No. not found in the specifications was set and
input for the common variables.
• When the tool length was measured manually, a nonexisting tool
wear compensation number was specified and the sensor was
turned ON. Specify the R register of the offset number correctly.
E04
DEV. NOT READY
×
• The input/output unit power is not ON.
• The cable is disconnected.
• Setting of the transfer speed (baud rate) does not agree.