2. Operation Messages on Setting And Display Unit
2.1 Operation Errors
I - 57
Error No.
Error message
Details
E201
UNIT NOT EQUIP
×
• The analog output unit is not mounted.
• Confirm the remote l/O unit.
• Prepare a unit having analog output.
• Check the connection (power and signal wires)
• Unit defect (replace unit)
E301 CONNECT
ERROR
×
• A socket connection attempt failed during Ethernet
communication.
• Check the host address, the setting of the port No. and that the
host computer is turned ON.
E302 LOGIN
ERR
×
• A login attempt failed during Ethernet communication. Check the
user name and password.
• Check the account settings, such as the home directory.
E303 TIME
OUT
×
• Transmission of a file with Ethernet communication ended
because of timeout.
E311 DOWNLOAD
ERR
×
• An attempt to read a host file failed during Ethernet
communication.
E312 UPLOAD
ERR
×
• An attempt to write to a host file failed during Ethernet
communication.
E313 NO
FILE
×
• The file specified by host receive (host
→
IC) operation during
Ethernet communication is not found in the host.
• The file specified by host send (IC
→
host) operation during
Ethernet communication is not found in the IC card.
E314 FILE
DUPLICATE
×
• The file name specified to be stored by host receive (host
→
IC)
operation during Ethernet communication already exists in the IC
card.
• The file name specified to be loaded by host send (IC
→
host)
operation during Ethernet communication already exists in the
host.
E315
FILE WRITE ERR
×
• An attempt to write to the IC card failed during Ethernet
communication.
E316
FILE READ ERR
×
• An attempt to read a file from the IC card failed during Ethernet
communication.
E317 MEMORY
OVER
×
• IC card memory is full.
• NC memory is full.
E318
OVER FLOW ERR
×
• A host directory contains too many files.
E319 DIRECTORY
ERR
×
• An attempt to move a directory failed.
• In the IC card device, accessing a directory in the nineteenth
layer or more was attempted.
E320 HR437
UNEQU
×
• When backup or writing of the expansion cassette into/from the
FROM, the expansion cassette (HR437) was not mounted in
CBUS#1 or was incorrectly mounted.
• When backup or writing of the expansion cassette into/from the
FROM, a card other than the expansion cassette (HR437) was
mounted in CBUS#1.
• When the program memory was formatted to 1280m or more, the
expansion cassette (HR437) was not mounted in CBUS#1.