3. Program Error
I - 75
Error No.
Details
Remedy
P393
INC ERR (GEOMT)
The second geometric block was
specified by an incremental value.
• Specify this block by an absolute value.
P394
NO G01 (GEOMT)
The second geometric block contains no
linear command.
• Specify the G01 command.
P395
NO ADRS (GEOMT)
The geometric format is invalid.
• Recheck the program.
P396
PL CHG. (GEOMT)
A plane switching command was
executed during geometric command
processing.
• Execute the plane switching command
before geometric command processing.
P397
ARC ERR (GEOMT)
In geometric IB‚ the circular arc end point
does not contact or cross the next block
start point.
• Recheck the geometric circular arc command
and the preceding and following commands.
P398
NO GEOMETRIC 1B
Although the geometric IB specifications
are not included‚ a geometric command
is given.
• Check the specifications.
P421
PRAM. IN ERROR
• The specified parameter number or set
data is illegal.
• An illegal G command address was
input in parameter input mode.
• A parameter input command was input
during fixed cycle modal or nose R
compensation.
• Check the program.
P430
AXIS NOT RET.
• A command was issued to move an
axis‚ which has not returned to the
reference point‚ away from that
reference point.
• A command was issued to an axis
removal axis.
• Execute reference point return manually.
• The command was issued to an axis for
which axis removal is validated so invalidate
axis removal.
P431
NO 2nd REF. SPC
A command for second‚ third or fourth
reference point return was issued though
there are no such command
specifications.
• Check the specifications.
P434 COLLATION
ERR
One of the axes did not return to the start
position when the origin point collate
command (G27) was executed.
• Check the program.