5. CONNECTION OF UNIT
5.2 Unit Connection System Diagram
I
-11
5.2 Unit Connection System Diagram
F010 cable
CF10
RIO1
↑
0
1
CS1 CS2
↑
CF10
Remote I/O unit or terminator (R-TM)
Encoder (speed signal) 2 channels
Encoder (speed signal) 2 channels
DI
DI
DO
2
ST No.
↑
RIO1
RIO2
ENC1
ENC2
DI-L
DI-R
DO-L
DCIN
F050 cable
CF11
CF11
DCIN
R220 cable
R211 cable
R211 cable
R000 cable
R000 cable
R301 cable
R301 cable
R301 cable
M60/M600 Series
control unit
Base I/O unit
Additional
I/O card
HR211
24VDC
stabilized
power
Remote I/O unit
(FCU6-DX561)
Name Explanation
RIO1
This is connected to the base I/O unit.
RIO2
This is used to connect the terminator or to expand the remote I/O unit.
The remote I/O unit can be expanded by up to four stations.
ENC1
Connected with encoder via spindle amplifier.
ENC2
Connected with encoder via spindle amplifier.
DI-L
DI: 28 (Sink/Source)
DI-R
DI: 16 (Sink/Source)
DO-L
DO: 32 (Source)
ST No.
Set the station No. In the above example, "0, 1" is set for the base I/O, so set to "2". As this
unit occupies two stations, set this switch to an even number (0, 2, 4, 6).
(Note)
If an odd number (1, 3, 5, 9) is set, the station number for when an even number
(0, 2, 4, 6) is set will be selected.