5. CONNECTION OF UNIT
5.6 Connection of Encoder Speed Signal
I
-16
[Outline of connection]
GND
PC
∗
PC
1k
Ω
1k
Ω
10
0
Ω
ENC1/2
Spindle
amplifier
[Signal assignment table]
1st channel
X00
2nd channel
X01
3rd channel
X02
4th channel
X03
[Input specifications]
Item Specifications
Input voltage
Line receiver input (X00 to X03) (5VDC)
Input sensitivity
OFF
→
ON 4.5mA or more, ON
→
OFF 1.5mA or less
Input response time
X00 to X03 require 50µs or more for the second trigger to be validated.
The input pulse is detected at
.
Circuit insulation
Not insulated
Separate the signal wire from the drive line/power line when wiring.
Incorrect connections could damage the device, so always connect the cable to the
designated connector.
Do not connect or disconnect the connection cables between each unit while the power is
ON.
CAUTION
Downloaded from