3. INSTALLATION
3.1 General Specification
I
-3
3. INSTALLATION
3.1 General Specification
Unit name
Remote I/O unit
Type name
FCU6-DX561
During
operation
0 to 55°C
* Note
Ambient
temperature During
storage
–20 to 60°C
During
operation
45 to 75% RH (with no dew condensation)
Ambient
humidity
During
storage
45 to 80% RH (with no dew condensation)
Vibration resistance
4.9m/s
2
or less (during operation)
Shock resistance
29.4m/s
2
or less (during operation)
98m/s
2
or less (during transportation)
Working atmosphere
No corrosive gases, or high levels of dust or oil mist
Power noise
1kVA (P-P)
Withstand voltage
500VAC for one minute
Across entire output terminal batch and grounding terminal
Insulation resistance
5M
Ω
or more with 500VDC megger tester
Across entire output terminal batch and grounding terminal
General specifications
Grounding
Class D grounding
Use without grounding is possible if grounding is not possible.
Power voltage
24VDC +10%/
−
15%
(Must be insulated from 100VAC and 200VAC power supply)
Instantaneous stop
tolerance time
Operation continues when power instantaneously stops
for 4ms or less.
Power fuse
Chip type fuse incorporated
(SSTC 0.8A Maker: SOC UL198G approved, CSA C22.2 No. 59.2)
Power consumption
Approx. 10W (Only control section; excludes input/output section)
Rush current
Approx. 20A/1ms, approx. 5A/10ms
Sensor power
None
Weight 1.8kg
Power sp
ecific
ations
Unit size
Refer to Appendix.
* Note
If the ambient temperature is 55°C or more, lower to 55°C or less with forced cooling.