Chapter 6 Detector Specifications
6–3
6-2 Scale I/F unit
6-2-1 Outline
MDS-B-HR outline
(1) The scale analog output source waves are interpolated to generate high resolution position data.
This is effective for increasing the servo's high gain by increasing the detector's resolution.
(2) The linear motor's pole position data is generated with the source waves output by the
MDS-B-MD (pole detection unit).
(3) 1-scale, 2-driver operation is possible with the signal branching function (with type class).
6-2-2 Type configuration
MDS-B-HR type configuration
MDS-B-HR-
Protection format class
No symbol: IP65 P: IP67
Pole detection unit compatibility class
No symbol: Not MD compatible M: MD compatible
Signal branching function class
1: No. of outputs 1 2: No. of outputs 2 (with branching)
Scale output voltage class
1: Scale output voltage 1V
p-p
specifications
2: Scale output voltage 2 V
p-p
specifications