-194-
Error No.
Error Cause and Remedy
First 4
Digits
Last 5
Digits
L.3986
14n00
n= Mech.
No.
Err. message Disable force sense control.
Cause
JOG operation cannot be performed on your model while the force
sense control function is enabled.
Remedy
Disable the force sense control function.
L.3986
16n00
n= Mech.
No.
Err. message Unable to perform offset cancel. (Force sense control)
Cause
It is not possible to perform offset cancel while the force sense
control function is enabled.
Remedy
If performing offset cancel, disable the force sense control
function.
L.3987
01n00
n= Mech.
No.
Err. message Force sense control is disabled.
Cause
Force sense control is disabled, and so unable to execute the
command.
Remedy
Enable the force sense control function.
L.3987
02n00
n= Mech.
No.
Err. message Force sense control is enabled.
Cause
It is not possible to enable force sense control again while already
enabled.
Remedy
First disable the force sense control function, and then enable
again.
L.3987
04n00
n= Mech.
No.
Err. message Unable to execute the FsGChg command.
Cause
It is not possible to execute the FsGChg command when force
control gain change is not complete.
Remedy
Review the program so that the FsGChg command is executed
after force control gain change is complete.
L.3987
07n00
n= Mech.
No.
Err. message Unable to output log file.
Cause
FTP processing was not properly performed.
Remedy
Check the FTP related parameter setting.
Check the Ethernet cable connection.
Check the FTP server settings at the computer.
L.3987
08n00
n= Mech.
No.
Err. message The specified log file does not exist.
Cause
The log file for the No. specified with the FsOutLog command
does not exist.
Remedy
Check whether the log file No. is incorrect.
L.3987
10n00
n= Mech.
No.
Err. message Unable to change the force sense status variable.
Cause
The status variable setting is currently being used by the force
sense control function and so cannot be changed.
Remedy
If changing the setting, disable the force sense control function.
L.3987
11n00
n= Mech.
No.
Err. message Force sense log commands executed simultaneously.
Cause
It is not possible to create/output another file while creating (FsLog
Off command) or outputting (FsOutLog command) a force sense
log file.
Remedy
Process after force sense log file creation/output is complete.
Summary of Contents for MELFA BFP-A3614
Page 1: ...Mitsubishi Industrial Robot Robot Seminar Textbook Force Sensor Application BFP A3614 ...
Page 2: ......
Page 34: ... 23 2 F series a CR750 D controller ...
Page 35: ... 24 b CR751 D controller ...
Page 36: ... 25 c CR750 Q CR751 Q controller CPU module ...
Page 75: ... 64 MEMO Please use this page for your memo ...
Page 95: ... 84 MEMO Please use this page for your memo ...
Page 103: ... 92 MEMO Please use this page for your memo ...
Page 111: ... 100 MEMO Please use this page for your memo ...
Page 119: ... 108 MEMO Please use this page for your memo ...
Page 123: ... 112 MEMO Please use this page for your memo ...
Page 129: ... 118 MEMO Please use this page for your memo ...
Page 133: ... 122 MEMO Please use this page for your memo ...
Page 137: ... 126 MEMO Please use this page for your memo ...
Page 143: ... 132 MEMO Please use this page for your memo ...
Page 149: ... 138 MEMO Please use this page for your memo ...
Page 153: ... 142 MEMO Please use this page for your memo ...
Page 159: ... 148 MEMO Please use this page for your memo ...
Page 171: ... 160 MEMO Please use this page for your memo ...
Page 183: ... 172 MEMO Please use this page for your memo ...
Page 191: ... 180 MEMO Please use this page for your memo ...
Page 211: ......