-42-
(5) Filter time constant (FSFLCTL)
The force sensor data filter time constant can be changed.
When the sensor data is not stable or the robot vibrates during the force control, increasing the
constant solves the problem.
Increase the setting value···Decreases the vibration. However, because the sensor data delays,
the sensitivity of the force sense detection and force sense control are
lowered and the robot cannot react to micro force.
Decrease the setting value···Reacts to the micro force properly, but the robot is more likely to
vibrate.
Parameter Parameter
Name
No. of
Elements
Description
Factory Default
Setting
Force sensor
data filter
FSFLCTL
1 real
number
Sets the force sensor data filter time constant.
[Unit]: ms
[Setting range]: 0 to +1000.0
1.7
(6) Force Sensor Minimum Control Force (FSMINCTL)
The minimum control force of force sensor can be changed.
Even if the force sensor does not touch the workpiece, etc. during force sense control, the robot
may vibrate due to stationary noise of sensor data. In this case, increasing the minimum control
force solves the problem.
However, increasing the minimum control force widens the dead zone. Therefore, the sensitivity of
the force sense detection/force sense control will be deteriorated.
Parameter
Parameter
Name
No. of
Elements
Description
Factory
Default Setting
Force sensor
minimum
force control
FSMINCTL
6 real
numbers
Sets the minimum control force of the force sensor.
1st element: Minimum control force of force sensor Fx [N]
2nd element: Minimum control force of force sensor Fy [N]
3rd element: Minimum control force of force sensor Fz [N]
4th element: Minimum control force of force sensor Mx [Nm]
5th element: Minimum control force of force sensor My [Nm]
6th element: Minimum control force of force sensor Mz [Nm]
0.3, 0.3, 0.3,
0.03, 0.03,
0.03
Summary of Contents for MELFA BFP-A3614
Page 1: ...Mitsubishi Industrial Robot Robot Seminar Textbook Force Sensor Application BFP A3614 ...
Page 2: ......
Page 34: ... 23 2 F series a CR750 D controller ...
Page 35: ... 24 b CR751 D controller ...
Page 36: ... 25 c CR750 Q CR751 Q controller CPU module ...
Page 75: ... 64 MEMO Please use this page for your memo ...
Page 95: ... 84 MEMO Please use this page for your memo ...
Page 103: ... 92 MEMO Please use this page for your memo ...
Page 111: ... 100 MEMO Please use this page for your memo ...
Page 119: ... 108 MEMO Please use this page for your memo ...
Page 123: ... 112 MEMO Please use this page for your memo ...
Page 129: ... 118 MEMO Please use this page for your memo ...
Page 133: ... 122 MEMO Please use this page for your memo ...
Page 137: ... 126 MEMO Please use this page for your memo ...
Page 143: ... 132 MEMO Please use this page for your memo ...
Page 149: ... 138 MEMO Please use this page for your memo ...
Page 153: ... 142 MEMO Please use this page for your memo ...
Page 159: ... 148 MEMO Please use this page for your memo ...
Page 171: ... 160 MEMO Please use this page for your memo ...
Page 183: ... 172 MEMO Please use this page for your memo ...
Page 191: ... 180 MEMO Please use this page for your memo ...
Page 211: ......