Requirement for Compliance with LVD directive

The following products have shown compliance through direct
testing (of the identified standards below) and design analysis
(through the creation of a technical construction file) to the European
Directive for Low Voltage (73/23/EEC) when used as directed by the
appropriate documentation.

Type :

Programmable Controller (Open Type Equipment)

Models : MELSEC FX

2NC

 series manufactured

from August 1st, 1999

FX

2NC

-16EYR-T-DS

from October 1st, 2007

FX

2NC

-16EYR-T

*Compliance to BSEN61010-1 is claimed through virtue of direct

compliance to IEC1010-1 and Amendment 1.

Models :MELSEC FX

2N

 series manufactured

from July 1st, 1997

FX

2N

-16EYR-ES/UL

from August 1st, 2005 FX

2N

-8ER-ES/UL

FX

2N

-8EYR-ES/UL

For the products above, PLC’s manufactured
before March 31st, 2002 are compliant with IEC1010-1
PLC’s manufactured from April 1st, 2002 to April 30th, 2006 are
compliant with EN61131-2:1994+A11:1996+A12:2000
PLC’s manufactured after May 1st, 2006 are compliant with
EN61131-2:2003

Caution for compliance with EC Directive

Installation in Enclosure

Programmable logic controllers are open-type devices that must be
installed and used within conductive control boxes. Please use the
FX

3UC

 Series programmable logic controllers while installed in

conductive shielded control boxes. Please secure the control box lid
to the control box (for conduction). Installation within a control box
greatly affects the safety of the system and aids in shielding noise
from the programmable logic controller.

Caution for Analog Products in use

The analog special adapters have been found to be compliant to the
European standards in the aforesaid manual and directive. However,
for the very best performance from what are in fact delicate
measuring and controlled output device Mitsubishi Electric would like
to make the following points;
As analog devices are sensitive by nature, their use should be
considered carefully. For users of proprietary cables (integral with
sensors or actuators), these users should follow the manufacturers’
installation requirements.
Mitsubishi Electric recommends that shielded cables be used. If no
other EMC protection is provided, then users may experience
temporary loss of accuracy b10%/-10% in very heavy
industrial areas.
However, Mitsubishi Electric suggests that when adequate EMC
precautions are followed with general good EMC practice for the
users complete control system, users should expect normal
accuracy as specified in this manual.

- Sensitive analog cables should not be laid next to or bound with 

high voltage cabling. Where possible, users should run analog 
cables separately.

- Good cable shielding should be used. When grounding the 

shield - ensure that no loops are accidentally created.

- When reading analog values, EMC induced errors can be 

smoothed out by averaging the readings. This can be achieved 
either through functions on the analog special adapter/block or 
through the user’s program in the FX

3UC

 Series PLC main unit.

Associated manuals

FX

3UC

 Series PLC (main unit) comes with this document (hardware

manual).
For a detailed explanation of the FX

3UC

 Series hardware and

information on PLC programming instructions and special extension
unit/block, refer to the relevant documents.

EN61131-2:2003

Programmable
controllers
- Equipment 

requirements and 
tests

Compliance with all relevant aspects of
the standard.

Radiated Emissions

Mains Terminal Voltage Emissions

RF immunity

Fast Transients

ESD

   Surge

Voltage drops and interruptions

Conducted

Power magnetic fields

Standard

Remark

IEC1010-1:1990

      /A1:1992

BSEN61010-1 :1993 *

Safety requirements for 
electrical equipment for 
measurement, control, and 
laboratory use

- General requirements

The equipment has been
assessed as a component for
fitting in a suitable enclosure
which meets the requirements of
IEC 1010-1:
1990+A1:1992

Standard

Remark

IEC1010-1:1990
            /A1:1992

Safety requirements for 
electrical equipment for 
measurement, control, and 
laboratory use

- General requirements

The equipment has been
assessed as a component for
fitting in a suitable enclosure
which meets the requirements of
IEC 1010-1:
1990+A1:1992

EN61131-2:1994      :2003
           /A12:2000
           /A11:1996

Programmable controllers

- Equipment requirements 

and tests

The equipment has been
assessed as a component for
fitting in a suitable enclosure
which meets the requirements of
EN61131-2:
1994+A11:1996+A12:2000,
:2003

Standard

Remark

Manual name

Manual No.

Description

FX

3UC

 Series 

User's Manual 
- Hardware 
Edition

JY997D28701

MODEL CODE: 

09R519

Explains the FX

3UC

 Series 

PLC specifications for I/O, 
wiring, installation, and 
maintenance.

FX

3U

/FX

3UC

 

Series 
Programming 
Manual 
- Basic & Applied 
Instruction Edition

JY997D16601

MODEL CODE: 

09R517

Describes PLC 
programming for basic/
applied instructions STL/
SFC programming and 
system devices.

FX Series User’s 
Manual - Data 
Communication 
Edition

JY997D16901

MODEL CODE: 

09R715

Explains N:N Network, 
parallel link, computer link, 
non-protocol 
communication by RS 
instructions/FX

2N

-232IF.

FX

3U

 / FX

3UC

 

Series 
User's Manual 
- Analog Control 
Edition

JY997D16701

MODEL CODE: 

09R619

Describes specifications for 
analog control and 
programming methods for 
the FX

3U

 / FX

3UC

 Series 

PLC.

How to obtain manuals

For product manuals or documents, consult with the Mitsubishi
Electric dealer from who you purchased your product.

Incorporated Items

Verify that the following product and items are included in the
package.

1.

Outline

1.1

Part names 

 

FX

3U

 / FX

3UC

 

Series 
User's Manual 
- Positioning 
Control Edition

JY997D16801

MODEL CODE: 

09R620

Explains the positioning 
control specifications of the 
FX

3U

 / FX

3UC

 Series and 

programming procedures

Included Items

Main units

FX

3UC

-

MT/D

Product

1 unit

FX

2NC

-100MPCB 

[1m (3’ 3"), three wire]

1 cable

FX

2NC

-100BPCB 

[1m (3’ 3"), two wire]

1 cable

Manuals [Japanese version, 
English version]

1 manual 

each

FX

3UC

-

MT/DSS

Product

1 unit

FX

2NC

-100MPCB 

[1m (3’ 3"), three wire]

1 cable

Manuals [Japanese version, 
English version]

1 manual 

each

Input / output extension blocks

FX

2NC

-

EX

FX

2NC

-16EX-T

Product

1 unit

FX

2NC

-10BPCB1 [0.1m (3.93"), 

double-ended]

1 cable

FX

2NC

-

EX-DS

FX

2NC

-16EX-T-DS

FX

2NC

-

EYT

FX

2NC

-

EYT-DSS

FX

2NC

-16EYR-T

FX

2NC

-16EYR-T-DS

Product

1 unit

Manual name

Manual No.

Description

[2]

[5]

Front panel

[11]

[6]

[12]

[2]

[8]

[4]

[2]

[6]

[14]

Under side

[4]

[15]

[7]

[9]

[10]

[6]

No.

Name

[1]

Memory cassette dummy cover

[2]

Special adapter connecting hooks

[3]

Special adapter connector cover

[4]

DIN rail mounting hooks

[5]

POW LED

On while power is on the PLC.

RUN LED

On while the PLC is running.

BAT LED

Lights when the battery voltage drops.

ERR LED

Flashing when a program error occurs.

Lights when a CPU error occurs.

[6]

FX

2NC

/FX

3UC

 Extension block connecting hooks

[7]

Input LED

[8]

Output LED

[9]

Input connector

[10] Output connector

[11] Peripheral device connecting connector (RS-422)

[12] RUN/STOP switch

[13] FX

2NC

/FX

3UC

 Extension block connecting connector cover

[14] Power connector for main unit

[15] Battery cover

Green
Green

Red
Red

[1]

[3]

Left side

[2]

[4]

[4]

[13]

Right side

[2]

[6]

[6]

Display LED

[5]

Summary of Contents for MELSEC FX3U-485ADP-MB

Page 1: ...the PLC is transported with the BAT LED on or the battery exhausted the battery backed data may be unstable during transportation The PLC is a precision instrument During transportation avoid impacts larger than those specified in Section 2 1 Failure to do so may cause failures in the PLC After transportation verify the operations of the PLC STARTUP AND MAINTENANCE PRECAUTIONS Models MELSEC FX2N s...

Page 2: ...e standard Radiated Emissions Mains Terminal Voltage Emissions RF immunity Fast Transients ESD Surge Voltage drops and interruptions Conducted Power magnetic fields Standard Remark IEC1010 1 1990 A1 1992 BSEN61010 1 1993 Safety requirements for electrical equipment for measurement control and laboratory use General requirements The equipment has been assessed as a component for fitting in a suitab...

Page 3: ...eries terminal blocks Battery and memory cassettes Notes When a dust proof sheet is supplied with an extension unit block keep the sheet applied to the ventilation slits during installation and wiring work To prevent temperature rise do not install the PLC on a floor a ceiling or a vertical surface Install it horizontally on a wall as shown in section 2 2 Keep a space of 50mm 1 97 or more between ...

Page 4: ... lower connector when performing crossover wiring for the later block In case of the FX2NC EX T DS removal of the connector cover is unnecessary Black Black Red Red Green Ground a Press here Self made power cable To use self made power cables use the following wire and connector suggestions 2 5 Connection to input output connector The input output connectors of the Main units conform to MIL C 8350...

Page 5: ...put output wiring 50 to 100m 164 1 to 328 1 long will cause almost no problems of noise but generally the wiring length should be less than 20m 65 7 to ensure the safety Extension cables are easily affected by noise Lay the cables at a distance of at least 30 to 50mm 1 19 to 1 97 away from the PLC output and other power lines Item Specification Supply voltage 24V DC 20 15 1 Ripple Voltage p p 5 or...

Page 6: ...ing For more details refer to the FX3UC Series User s Manual Hardware Edition 3 4 1 Transistor output specifications 1 When using an instruction related to pulse train output or positioning make sure to set the load current to 10 to 100mA 5 to 24V DC 2 The transistor OFF time is longer under lighter loads For example under a load of 24V DC 40mA the response time is approx 0 3ms When response perfo...

Page 7: ...rve simultaneous ON ratio 80 55 C Ambient temperature applicable 20 45 C When extension blocks units are connected Supply voltage 24V DC 40 C 60 65 When only the main unit is used without extension blocks units 3 5 3 Cautions on relay output wiring For more details refer to FX3UC Series User s Manual Hardware Edition 1 Protection circuit for load short circuits A short circuit at a load connected ...

Page 8: ... Y2 Y3 Y4 Y5 Y6 Y7 V1 V1 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 OUT Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 V0 V0 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Lower Notch Upper IN X0 X1 X2 X3 X4 X5 X6 X7 COM COM COM X0 X1 X2 X3 X4 X5 X6 X7 COM Lower Upper OUT Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 COM1 COM1 COM2 Y0 Y1 Y2 Y3 Y4 Y5 Y6 Y7 COM2 Lower Upper This manual confers no industrial property rights or any rights of any other kind nor does it confer any patent ...

Reviews: