60
8 Application Steps
8.4 Format Data
Basic Formatting
The type of a format which is used when outputting codes read by the code reader can be set. Output contents can be
configured for each code separately, or common output settings can be configured under the [Universal] tab. Configuring
either one of the settings is recommended.
Select the checkbox of "Standard" for codes to set.
After selecting contents to be output in "Data," click the [Add] button to add output data.
When adding CR/LF to the end of output data, select the checkbox of "CR/LF."
By clicking the [Test] button, the result of the last read code which is output by the set format can be checked on the right
side window.
* When outputting the read code result enclosed by control character codes such as STX (Start of Text) and ETX (End of
Text), set hexadecimal ASCII codes for leading and terminating text respectively.
Leading Text: \x02 Terminating Text: \x03 (Hexadecimal characters can be specified by entering \xnn (nn indicates
hexadecimal ASCII codes).)
Ò
Ó
Ô
Õ