66
8 Application Steps
8.5 Inputs/Outputs
Outputs
Output signals are set.
Strobe
When using external lights, this function can provide strobe signals to the lights.
Read/No Read
This function can output signals respectively when a code is read or not read.
Validation Failure
A signal is output when validation is failed.
Trigger Overrun/Buffer Overflow
A signal is output when each error occurs.
Trigger Overrun: It occurs when a trigger is input before the code reader prepares for an image acquisition, such as when a
trigger is input while an image is acquired.
Buffer Overflow: It occurs when there is no storage area for acquired images. This indicates that the processing cannot keep
up with the volume of acquired images. The overflow occurs when the decoding time takes longer than the image/trigger
interval.
Open/Closed
A signal is output as follows when an event is occurred.
Open: A signal ON
OFF
Closed: A signal OFF
ON
Pulse Width
The pulse width of a signal is set.
Summary of Contents for Melsensor CF26-LR
Page 2: ......
Page 11: ...1 OVERVIEW 1 1 Overview of DataMan Setup Tool for MELSENSOR 9 1 MEMO ...
Page 13: ...2 SetupTool INSTALLATION 2 1 Installation 11 2 MEMO ...
Page 15: ...3 CODE READER SETUP FLOW CHART 3 1 Setup Flow Chart 13 3 MEMO ...
Page 17: ...4 CONFIGURATIONS 4 1 Configuration and Wiring of CF26 CF37 Series 15 4 MEMO ...
Page 92: ...90 APPX Appendix 5 Supplemental Remarks for Tuning 2 MEMO ...
Page 111: ......