88
APPX
Appendix 4 Supplemental Remarks for Tuning (1)
Appendix 4
Supplemental Remarks for Tuning (1)
Adjusting a reading region
Tuning after setting a lightening pattern
A lightening pattern can be set to turn ON and OFF the lights by clicking each light on the front view of the code reader which
is displayed in [Optimize Image] of [Application Steps].
When executing tuning by clicking [
] on the right side of the [Tune] button and disabling "Tune Light Banks," tuning with the
set lightening pattern is executed.
Focus adjustment in Tune may be failed if a work is a 3D
object.
Additionally, a specific code may not be tuned when multiple
codes are present within the reading range.
The corrective action for these cases can be taken by
adjusting the reading region. The right image shows works
with different height that are captured on the right and left
side of the image. The bottom right code of the image is
tuned by adjusting the reading region which is displayed with
a blue frame.
Smaller reading region can shorten the tuning and reading
time, and improve the reading rate.