20
5 CONNECTING with SetupTool
5.2 Starting SetupTool
5.2
Starting SetupTool
Start SetupTool.
The [Connect] in the [Home] tab is displayed immediately after starting SetupTool.
When SetupTool recognizes a code reader, "Name," "Address," "Firmware Version," and "Status" of the code reader are
displayed under the "Network" section and the information can be checked.
Whether the IP address matches with the one set in the connected personal computer can be checked in "Status."
<When the status is "Misconfigured">
This indicates the IP address of the code reader and the personal computer are not matched. Either one of the addresses
needs to be changed.
<When the status is "Discovered">
This indicates the IP addresses are matched. A connection can be made by selecting the code reader icon and click the
[Connect] button on the lower right of the screen.
Precautions
■
When a code reader is not recognized
When a code reader is not recognized, try the following operations:
• Click [Update].
• Check that the cables are properly connected.
• Allow the communication in the settings of a firewall or security software.
For details, refer to the following:
Page 21 When communication with DataMan Setup Tool is not allowed by a firewall
Summary of Contents for Melsensor CF26-LR
Page 2: ......
Page 11: ...1 OVERVIEW 1 1 Overview of DataMan Setup Tool for MELSENSOR 9 1 MEMO ...
Page 13: ...2 SetupTool INSTALLATION 2 1 Installation 11 2 MEMO ...
Page 15: ...3 CODE READER SETUP FLOW CHART 3 1 Setup Flow Chart 13 3 MEMO ...
Page 17: ...4 CONFIGURATIONS 4 1 Configuration and Wiring of CF26 CF37 Series 15 4 MEMO ...
Page 92: ...90 APPX Appendix 5 Supplemental Remarks for Tuning 2 MEMO ...
Page 111: ......