1 - 4
1. FUNCTIONS AND CONFIGURATION
1.4 Standard specification
1.4.1 Converter unit
Model
Item
MP-HP30K
Voltage/frequency
3-phase 200 to 230VAC, 50/60Hz
Permissible voltage
fluctuation
3-phase 170 to 253VAC, 50/60Hz
Main circuit
power supply
Permissible frequency
fluctuation
Within 5%
Voltage/frequency
1-phase 200 to 230VAC, 50/60Hz
Permissible voltage
fluctuation
1-phase 170to 235VAC, 50/60Hz
Permissible frequency
fluctuation
Within 5%
Control power
supply
Power consumption
50W
Rated output
30kw
Regenerative power
(Using regenerative brake option)
One MR-RB139: 1300W
Three MR-RB139s: 3900W
Protective function
Regenerative overvoltage shutoff, overload shutoff (electronic thermal protector)
Regenerative alarm protection, undervoltage, instantaneous power failure protection
Structure
Open(IP00)
0 to 55 [°C] (non-freezing)
Ambient temperature
32 to 131 [°F] (non-freezing)
Ambient humidity
90%RH or less (non-condensing)
20 to 65 [°C] (non-freezing)
Storage temperture
4 to 149 [°F] (non-freezing)
Storage humidity
90%RH or less (non-condensing)
Ambient
Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitud
Max. 1000m (3280 ft) above sea level
5.9 [m/s
2
] or less
Environment
Vibration
19.4 [ft/s
2
] or less
Weight
[Kg] [lb]
22 [48.502]
1.4.2 Servo amplifier
Servo
amplifier
Item
MR-H30K
Voltage/frequency
Single-phase 200 to 230VAC, 50/60Hz
Permissible voltage
fluctuaion
Single-phase 170 to 253VAC, 50/60Hz
Permissible frequency
fluctuation
Within 5%
Control power
supply
Power consumption
50W
Main circuit power supply
The main circuit power of the servo amplifier is supplied by the converter unit.
System
Sine-wave PWM control, current control system
Structure
Open (IP00)
Ambient temperature
0 to 55 [°C] (non-freezing), storage: 20 to 65 [°C] (non-freezing)
Humidity
90%RH or less (non-condensing), storage: 90%RH or less (non-condensing)
Ambience
Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude
Max. 1000m (3280ft) above sea level
Environment
Vibration
5.9 [m/s
2
] or less
Weight
Kg [lb] 47 [103.617]
Function
Refer to the corresponding Servo Amplifier Instruction Manual of 22kW or less.
Summary of Contents for Melservo-H Series
Page 11: ... 4 MEMO ...
Page 23: ...1 12 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 41: ...3 16 3 SIGNALS AND WIRING MEMO ...
Page 49: ...4 8 4 DISPLAY SECTION AND OPERATION SECTION OF THE CONVERTER UNIT MEMO ...
Page 61: ...7 6 7 OUTLINE DIMENSIONAL DRAWINGS MEMO ...
Page 81: ...9 16 9 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...
Page 91: ...App 10 APPENDIX MEMO ...