9. OPTIONS AND AUXILIARY EQUIPMENT
9.1.4 Heat sink outside mounting attachment (MR-ACN)
Use the heat sink outside mounting attachment to mount the heat generation area of the servo amplifier
in the outside of the control box to dissipate servo amplifier-generated heat to the outside of the box and
reduce the amount of heat generated in the box, thereby allowing a compact control box to be designed.
In the control box, machine a hole having the panel cut dimensions, fit the heat sink outside mounting
attachment to the servo amplifier with the fitting screws (4 screws supplied), and install the servo
amplifier to the control box.
The environment outside the control box when using the heat sink outside mounting attachment should
be within the range of the servo amplifier operating environment conditions.
(1) Panel cut dimensions
[Unit : mm(in)]
Variable Dimensions
Servo amplifier
Converter unit
Attachment
A
B
C
D
MR-HP30KA
MR-ACNP55K
156
(6.16)
110
(4.33)
205
(8.09)
190
(7.48)
MR-H30K
MR-ACN55K
406
(15.98)
360
(14.17)
455
(17.91)
440
(17.32)
B
C
A
15
D
4-M10 Screw
60
5
(23.
82)
57
5
(22.
64)
44
4
(17.
48)
(0.
59)
(2) Fitting method
Attachment
a. Assembling the heat sink outside mounting attachment
b. Installation to the control box
control
box
Attachment supplied to
the servo amplifier(Note)
Note: Remove the attachment supplied and fit it in the specified position.
Square
hole
Summary of Contents for Melservo-H Series
Page 11: ... 4 MEMO ...
Page 23: ...1 12 1 FUNCTIONS AND CONFIGURATION MEMO ...
Page 41: ...3 16 3 SIGNALS AND WIRING MEMO ...
Page 49: ...4 8 4 DISPLAY SECTION AND OPERATION SECTION OF THE CONVERTER UNIT MEMO ...
Page 61: ...7 6 7 OUTLINE DIMENSIONAL DRAWINGS MEMO ...
Page 81: ...9 16 9 OPTIONS AND AUXILIARY EQUIPMENT MEMO ...
Page 91: ...App 10 APPENDIX MEMO ...