Part 3: Review on Replacement of MR-J2S-_B_ with MR-J4-_B_
3 - 27
MR-J2S-_B_ MR-J4-_B_
No.
Name and function
Initial
value
No.
Name and function
Initial
value
25 Low-pass filter/adaptive vibration suppression control
Used to select the low-pass filter/adaptive vibration
suppression control.
0000h PB23 Low-pass
filter
selection
Used to select the shaft resonance suppression filter.
Setting
digit
Explanation
Initial
value
_ _ _ X Shaft resonance suppression filter selection
0: Automatic
1: Manual setting
2: Disabled
When "Enabled (_ _ _ 1)" in "Machine
resonance suppression filter 4 selection" of
[Pr. PB49] is selected, shaft resonance
suppression filter cannot be used.
0h
0000h
No
corresponding
parameter
(Machine resonance filters can be automatically adjusted
with PB01.)
27 Analog monitor 1 offset
Used to set the offset voltage of Analog monitor 1 (MO1)
output.
0
PC11 Analog monitor 1 offset
Used to set the offset voltage of MO1 (Analog monitor 1).
0
28 Analog monitor 2 offset
Used to set the offset voltage of Analog monitor 2 (MO2).
0
PC12 Analog monitor 2 offset
Used to set the offset voltage of MO2 (Analog monitor 2).
0
30 Zero
speed
Used to set the output range of zero speed signal (ZSP).
50 PC07
Zero
speed
Used to set the output range of ZSP (Zero speed
detection).
ZSP (Zero speed detection) has the hysteresis of 20
[r/min] or 20 [mm/s]
50
31 Error excessive alarm level
Used to set the range where the excess droop pulse alarm
is generated.
Note: The setting unit for servo amplifier of software version
B1 or later is 0.025 rev. Note: The setting unit for
servo amplifier before software version B1 is 0.1 rev.
80
PC01 Error excessive alarm level
Set error excessive alarm level.
The setting unit for rotary servo motor is "rev". If "0" is set,
it becomes 3 rev. The setting value exceeding 200 rev will
be clamped at 200 rev.
0
PC06 Function selection C-3
Used to select the setting unit for error excessive alarm
level to be set in [Pr. PC01]. This parameter cannot be
used in the speed control mode and torque control mode.
Setting
digit
Explanation
Initial
value
_ _ _ X For manufacturer setting
0h
_ _ X _
0h
_ X _ _
0h
X _ _ _ Error excessive alarm level unit
selection
0
:
1 rev (unit)
1
:
0.1 rev (unit)
2
:
0.01 rev (unit)
3
:
0.001 rev (unit)
0h
0000h
0
Low-pass filter selection
0: Available (Automatic adjustment)
1: Disabled
When available is selected, the filter in
the zone expressed by the following
formula is automatically set.
For 1 kW or less
VG2 setting value × 10
[Hz]
2
π
× (1 + GD2 setting value × 0.1)
For 2 kW or more
VG2 setting value × 5
[Hz]
2
π
× (1 + GD2 setting value × 0.1)
Adaptive vibration suppression control
selection
0: Disabled
1: Enabled
Usually, machine resonance
frequency is detected, and a filter
corresponding to the resonance is
generated to control the machine
vibration.
2: Maintenance
Until then, detection of machine
resonance is stopped by keeping the
characteristics of the filter generated
until that moment.
Adaptive vibration suppression control
selection
Set the sensitiveness to detect the
machine resonance.
0: Normal
1: High sensitive
Summary of Contents for MELSERVO-J2-Super Series
Page 18: ...Part 1 Summary of MR J2S MR J2M Replacement 1 1 Part 1 Summary of MR J2S MR J2M Replacement ...
Page 31: ...Part 1 Summary of MR J2S MR J2M Replacement 1 14 MEMO ...
Page 109: ...Part 3 Review on Replacement of MR J2S _B_ with MR J4 _B_ 3 32 MEMO ...
Page 161: ...Part 4 Review on Replacement of MR J2S _CP_ CL_ with MR J4 _A_ RJ 4 52 MEMO ...
Page 239: ...Part 6 Review on Replacement of MR J2M with MR J4 6 20 MEMO ...
Page 240: ...Part 7 Common Reference Material 7 1 Part 7 Common Reference Material ...
Page 284: ...Part 7 Common Reference Material 7 45 Click Update Project ...
Page 342: ...Part 8 Review on Replacement of Motor 8 1 Part 8 Review on Replacement of Motor ...
Page 409: ...Part 8 Review on Replacement of Motor 8 68 MEMO ...
Page 461: ...Part 9 Review on Replacement of Optional Peripheral Equipment 9 52 MEMO ...
Page 462: ...Part 10 Startup Procedure Manual 10 1 Part 10 Startup Procedure Manual ...