5. PARAMETERS
5 - 22
Setting
Output item
Description
Setting
Output item
Description
4 Current
command
Max. current command
(Max. torque command)
CW direction
CCW direction
Max. current command
(Max. torque command)
0
8[V]
-8[V]
5 Speed
command
Max. speed
CW direction
CCW direction
Max. speed
0
8[V]
-8[V]
6
Droop pulses
(Note 1, 2, 3)
( 10V/100 pulses)
100[pulse]
CW direction
CCW direction
100[pulse]
0
10[V]
-10[V]
7
Droop pulses
(Note 1, 2, 3)
( 10V/1000 pulses)
1000[pulse]
CW direction
CCW direction
1000[pulse]
0
10[V]
-10[V]
8
Droop pulses
(Note 1, 2, 3)
( 10V/10000 pulses)
10000[pulse]
CW direction
CCW direction
10000[pulse]
0
10[V]
-10[V]
9
Droop pulses
(Note 1, 2, 3)
( 10V/100000 pulses)
100000[pulse]
CW direction
CCW direction
100000[pulse]
0
10[V]
-10[V]
D Bus
voltage
400[V]
0
8[V]
E
Speed command 2
(Note 2, 4)
Max.
CW direction
CCW direction
Max. speed
0
8[V]
-8[V]
Note 1. Encoder pulse unit.
2. Cannot be used in the torque loop mode.
3. Cannot be used in the speed loop mode.
4. This setting can be used with the servo amplifier whose software version is B3 or later and with MR Configurator whose software
version is C5 or later.
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...