10. CHARACTERISTICS
10 - 2
10.2 Power supply equipment capacity and generated loss
(1) Amount of heat generated by the servo amplifier
Table 10.1 indicates servo amplifiers' power supply capacities and losses generated under rated load. For
thermal design of an enclosure, use the values in Table 10.1 in consideration for the worst operating
conditions. The actual amount of generated heat will be intermediate between values at rated torque and
servo off according to the duty used during operation. When the servo motor is run at less than the
maximum speed, the power supply capacity will be smaller than the value in the table, but the servo
amplifier's generated heat will not change.
Values shown in the table are the values when same servo motors are used for the A-axis and the B-axis.
When using different servo motors for the A-axis and the B-axis, calculate the mean of the two servo motor
values, and use the mean value as a reference.
Table 10.1 Power supply capacity and generated heat per servo amplifier at rated output
(Note 2)
Servo amplifier-generated heat [W]
Area required for
heat dissipation
Servo motor 2
(Note 1)
Power supply
capacity [kVA]
At rated torque
With servo off
[m
2
]
HF-KP053 0.6 35 15 0.7
HF-KP13 0.6 35 15 0.7
HF-KP23 1
35
15
0.7
HF-KP43 1.8 55 15 1.1
HF-KP73 2.6 85 15 1.7
HF-MP053 0.6 35 15 0.7
HF-MP13 0.6 35 15 0.7
HF-MP23 1
35
15
0.7
HF-MP43 1.8 55 15 1.1
HF-MP73 2.6 85 15 1.7
HF-SP51 2.0 55 15 1.1
HF-SP81 3.0 90 15 1.8
HF-SP52 2.0 55 15 1.1
HF-SP102 3.4 90 15 1.8
HC-LP52 2.0 55 15 1.1
HC-LP102 3.4 90 15 1.8
HC-UP72 2.6 85 15 1.7
HF-JP53
2.0 55 15 1.1
HF-JP73
2.6 85 15 1.7
HF-JP103 3.4 90 15 1.8
Note 1. Note that the power supply capacity will vary according to the power supply impedance. This value is
applicable when the Power factor improving AC reactor is not used.
2. Heat generated during regeneration is not included in the servo amplifier-generated heat. To calculate heat
generated by the regenerative option, refer to section 11.2.
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...