11. OPTIONS AND AUXILIARY EQUIPMENT
11 - 12
(b) Internal wiring diagram
MR-EKCBL20M-L
Servo amplifier side
Encoder side
P5
LG
1
2
MR
MRR
3
4
3
7
9
SD
Plate
1
2
8
9
LG
MR
MRR
SHD
P5
BAT
BAT
(Note)
MR-EKCBL30M-L
Servo amplifier side
Encoder side
P5
LG
1
2
MR
MRR
3
4
MDR
8
5
3
7
4
MD
7
9
SD
1
2
8
9
LG
MR
MRR
MDR
MD
SHD
P5
6
CONT
BAT
BAT
Plate
(Note)
MR-EKCBL20M-H
Servo amplifier side
Encoder side
P5
LG
1
2
MR
MRR
3
4
3
7
9
SD
1
2
8
9
LG
MR
MRR
SHD
P5
BAT
BAT
(Note)
Plate
MR-EKCBL30M-H
MR-EKCBL40M-H
MR-EKCBL50M-H
Servo amplifier side
Encoder side
P5
LG
1
2
MR
MRR
3
4
MDR
8
5
3
7
4
MD
7
9
SD
1
2
8
9
LG
MR
MRR
MDR
MD
SHD
P5
6
CONT
BAT
BAT
(Note)
Plate
Note. Always make connection for use in an absolute position detection system. Wiring is not necessary for use in an incremental
system.
When fabricating the cable, use the wiring diagram corresponding to the length indicated below.
Applicable wiring diagram
Cable bending life
Less than 30m
30m to 50m
Standard MR-EKCBL20M-L
MR-EKCBL30M-L
Long bending life
MR-EKCBL20M-H
MR-EKCBL30M-H
MR-EKCBL40M-H
MR-EKCBL50M-H
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...