13. USING A LINEAR SERVO MOTOR
13 - 10
CAUTION
Do not modify the equipment.
The cables such as power cables deriving from the primary side (coil) cannot stand
the long-term bending action. Avoid the bending action by fixing to the movable part,
etc. Also, use the cable that stands the long-term bending action for the wiring to the
servo amplifier.
13.4.1 Precautions on this chapter
The following items are not described in this chapter. For details of these items, refer to the below item.
Item Reference
Explanation of Power Supply System
Section 3.3
Signal (device) explanations
Section 3.5
Alarm occurrence timing chart
Section 3.6
Interfaces
Section 3.7 (excluding the internal connection diagram)
Processing of cable shield external
conductor
Section 3.8
SSCNET cable connection
Section 3.9
Grounding Section
3.12
Control axis selection
Section 3.13
13.4.2 Power supply system circuit connection example
CAUTION
Always connect a magnetic contactor between the power supply and the main circuit
power supply (L1, L2, and L3) of the servo amplifier, in order to configure a circuit
that shuts down the power supply on the side of the servo amplifier’s power supply. If
a magnetic contactor is not connected, continuous flow of a large current may cause
a fire when the servo amplifier malfunctions.
Shut off the main circuit power supply when alarms are occurring in both of the A-
axis and the B-axis.
Otherwise, a regenerative transistor fault or the like may
overheat the regenerative resistor, causing a fire.
Check the servo amplifier model, and then input proper voltage to the servo amplifier
power supply. If input voltage exceeds the upper limit, the servo amplifier will break
down.
Connecting a linear servo motor for different axis to the CNP3A or CNP3B connector
may cause a malfunction.
POINT
Even if alarm has occurred, do not switch off the control circuit power supply.
When the control circuit power supply has been switched off, optical module does
not operate, and optical transmission of SSCNET communication is interrupted.
Therefore, the servo amplifier on the rear axis displays "AA" at the indicator and
turns into base circuit shut-off. The linear servo motor stops with starting dynamic
brake.
For details of each signal, refer to section 3.3.
Wire the power supply/main circuit as shown below so that power is shut off and the servo-on command turned
off as soon as an alarm occurs, a servo forced stop is made valid, or a controller forced stop is made valid. A
molded-case circuit breaker (MCCB) must be used with the input cables of the main circuit power supply.
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...