13. USING A LINEAR SERVO MOTOR
13 - 38
13.6.2 Basic setting parameters (No.PA
)
(1) Parameter list
POINT
The parameter whose symbol preceded by * can be validated with the following
conditions.
* : Turn off the power and then on again, or reset the controller after setting the
parameter.
**: Turn off the power and then on again after setting the parameter.
No. Symbol
Name
Setting
(Note 1)
Factory
setting
(Note 2)
Unit
Reference
PA01 **STY Control
mode
Each
axis
0000h This
section
(2)
PA02 **REG Regenerative
option
Common 0000h
Section
5.1.4
PA03
*ABS Absolute position detection system
Each
axis
0000h This
section
(2)
PA04 *AOP1 Function selection A-1
Common 0000h
Section
5.1.6
PA05
This parameter is not used. Do not change the value.
0
PA06
1
PA07
1
PA08
ATU
Auto tuning mode
Each
axis
0001h
PA09
RSP
Auto tuning response
Each
axis
12
Section
5.1.7
PA10 INP In-position
range
Each
axis
100 pulse This
section
(2)
PA11
This parameter is not used. Do not change the value.
1000.0
PA12
1000.0
PA13
0000h
PA14
*POL Moving direction selection
Each
axis
0
PA15
*ENR Encoder output pulses
Each
axis
4000
PA16 *ENR2 Encoder output pulses 2
Each
axis
0
This
section
(2)
PA17 **MSR Linear servo motor series setting Linear servo motor type setting
Each
axis
0000h
PA18 **MTY
Each
axis
0000h
PA19
*BLK Parameter write inhibit
Each
axis
000Bh
Note 1. Each axis: Set a value for each of the A-axis and the B-axis.
Common: Common parameters for the A-axis and the B-axis. Set same values for the A-axis and the B-axis. If different values are
set, the last set value becomes valid.
2. Valid for the A-axis and the B-axis.
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...