14. USING A DIRECT DRIVE MOTOR
14 - 33
No. Symbol
Name
Each/
common
(Note 1)
Default
value
(Note 2)
Unit Reference
PB33 VRF1B Gain changing vibration suppression control vibration frequency setting
Each
100.0
Hz
PB34 VRF2B Gain changing vibration suppression control resonance frequency
setting
Each 100.0
Hz
Section
5.5.2
PB35
This parameter is not used. Do not change this value by any means.
0.00
PB36
0.00
PB37
100
PB38
0.0
PB39
0.0
PB40
0.0
PB41
1125
PB42
1125
PB43
0004h
PB44
0.0
PB45
0000h
Note 1. Each: Set parameters for each axis of A and B.
Common: Set parameters for common axis of A and B. Be sure to set the same value to the both axes. When the setting values are
different, the value set at last will be enabled.
2. The values are common in A-axis and B-axis.
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...