14. USING A DIRECT DRIVE MOTOR
14 - 57
Warning No.: 96
Name: Home position setting warning
Stop method: No stop (each-axis detection)
Warning description
Home position setting could not be made.
Display
Detail name
Cause
Check method
Check result
Action
96.1 In-position
error
at home
positioning
96.2 Command
input
error at home
positioning
Same as for the rotary servo motors.
Refer to section 8.4.
Alarm No.: 9F
Name: Battery warning
Stop method: No stop (each-axis detection)
Warning description
Absolute position detection system battery voltage is low.
Display
Detail name
Cause
Check method
Check result
Action
9F.1 Low battery
Same as for the rotary servo motors.
Refer to section 8.4.
9F.2 Battery
degradation
1)
It is not connected.
Connect the absolute
position storage unit.
The absolute position
storage unit has not
connected.
Check if the absolute
position storage unit is
connected.
It is connected.
Check 2).
2) The battery has
deteriorated. (detected by
encoder)
Replace the battery.
It is not repeatable.
Replace the battery.
Warning No.: 91
Name: Excessive regeneration warning
Stop method: No stop (common detection)
Warning description
There is a possibility that regenerative power may exceed permissible regenerative power of built-in
regenerative resistor or regenerative option.
Display
Detail name
Cause
Check method
Check result
Action
E0.1 Excessive
regeneration
warning
Same as for the rotary servo motors.
Refer to section 8.4.
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...