14. USING A DIRECT DRIVE MOTOR
14 - 70
3) Encoder cable c)
a) Connector details
e) Absolute position storage unit connector
f) Encoder connector
Straight plug: RM15WTPZ-12P(72)
Cord clamp: JR13WCCA-8(72)
(Hirose Electric)
Recommended cable: 20276 VSVPAWG
#23 6P KB-0492
(Note 2)
(Bando Densen)
1
MR
2
MRR
3
5
LG
4
BAT
7
6
12
THM1
9
8
P5
10
11
FG
THM2
VB
View seen from the wiring side. (Note 1)
Straight plug: RM15WTPZK-12S
Cord clamp: JR13WCCA-8(72)
(Hirose Electric)
Recommended cable: 20276 VSVPAWG
#23 6P KB-0492
(Note 2)
(Bando Densen)
1
MR
2
MRR
3
5
LG
4
BAT
7
6
12
THM1
9
8
P5
10
11
FG
THM2
VB
View seen from the wiring side. (Note 1)
Note 1.
2.
Do not connect anything to the pins shown as
.
Purchase from Toa Electric Industry Co. Ltd., Nagoya Branch
b) Internal wiring diagram
When the distance between the servo amplifier and the
direct drive motor is within 20m (Note)
P5
LG
9
10
MR
MRR
7
8
6
9
6
BAT
7
8
10
2
LG
MR
MRR
BAT
P5
THM1
THM1
11
11
THM2
THM2
1
1
VB
VB
2
FG
5
FG
5
c) Absolute position storage
unit connector
b) Encoder connector
Note. For cables of 20m or longer, contact your local sales office.
Refer to the following table for the required wires to fabricate the encoder cable.
Core size
Conductor resistance of
one core
Overall diameter
0.25mm
2
63.6 /km or less
8.2mm
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...