(7) Selection example of wires
To comply with the UL/CSA Standard, use UL-approved copper wires rated at 60/75 (140/167 ) for
wiring.
Wires (Note 1)
Servo amplifier
(Note 3)
L
1
L
2
L
3
L
11
L
21
(Note 2, 3)
U V W
P
C P
D
(Note 2)
B1 B2
THM1
THM2
24 0 PM
MR-J3W-
0303BN6
AWG19
AWG16
(Note 4)
MR-J3W-22B
MR-J3W-44B
MR-J3W-77B
MR-J3W-
1010B
2mm
2
(AWG14)
1.25mm
2
(AWG16)
0.2mm
2
(AWG24)
Note 1. Wires are selected based on the highest rated current among combining servo motors.
2. This wire size indicates the size of cable extension which is used when the wiring length exceeds 10m.
3. Use the crimping terminal specified as below for the PE terminal of the servo amplifier.
Crimping terminal: FVD2-4
Tool (body)
: YNT-1614
Manufacturer :
JST
Tightening torque: 1.2 N m
4. Insulator OD : 2.9mm
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...