5. PARAMETERS
5 - 7
(2) Auto tuning response (parameter No.PA09)
If the machine hunts or generates large gear sound, decrease the set value. To improve performance, e.g.
shorten the settling time, increase the set value.
Setting Response
Guideline for machine
resonance frequency [Hz]
Setting
Response
Guideline for machine
resonance frequency [Hz]
1
Low response
10.0
17
Middle response
67.1
2 11.3
18 75.6
3 12.7
19 85.2
4 14.3
20 95.9
5 16.1
21 108.0
6 18.1
22 121.7
7 20.4
23 137.1
8 23.0
24 154.4
9 25.9
25 173.9
10 29.2
26 195.9
11 32.9
27 220.6
12 37.0
28 248.5
13 41.7
29 279.9
14 47.0
30 315.3
15
52.9
31
355.1
16
Middle response
59.6
32
High response
400.0
5.1.8 In-position range
Parameter
No. Symbol
Name
Setting
Factory
setting
Unit
Setting
range
PA10
INP
In-position range
Each axis
100
pulse
0 to 65535
POINT
This parameter cannot be used in the speed control mode and the torque control
mode.
Set the range, where in position (INP-A/INP-B) is output, in the command pulse unit.
Servo motor droop pulses
In-position range [pulse]
Command pulse
Command pulse
Droop pulses
In-position (INP-A/INP-B)
ON
OFF
Summary of Contents for MELSERVO-J3W Series
Page 17: ...8 MEMO ...
Page 27: ...1 FUNCTIONS AND CONFIGURATION 1 10 MEMO ...
Page 87: ...4 STARTUP 4 14 MEMO ...
Page 117: ...5 PARAMETERS 5 30 MEMO ...
Page 129: ...6 GENERAL GAIN ADJUSTMENT 6 12 MEMO ...
Page 185: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 241: ...11 OPTIONS AND AUXILIARY EQUIPMENT 11 56 MEMO ...
Page 274: ...13 USING A LINEAR SERVO MOTOR 13 25 1 2 3 4 ...