52
6 TROUBLESHOOTING
6.2 Troubleshooting for drive unit
*1 After resolving the source of trouble, cool the equipment for approximately 30 minutes.
*2 The following shows three stop methods of DB, EDB, and SD.
DB: Dynamic brake stop (For a servo amplifier without the dynamic brake, the servo motor coasts.)
Coasts for MR-J4-03A6(-RJ) and MR-J4W2-0303B6. Note that EDB is applied when an alarm below occurs;
[AL. 30.1], [AL. 32.2], [AL. 32.4], [AL. 51.1], [AL. 51.2], [AL. 888]
SD: Forced stop deceleration
EDB: Electronic dynamic brake stop (available with specified servo motors only)
Refer to the following table for the specified servo motors. For other than the specified servo motors, the stop method of DB is applied.
*3 This is applicable when [Pr. PA04] is set to the initial value. The stop method of SD can be changed to DB with [Pr. PA04].
*4 The alarm can be canceled with the following settings:
When the fully closed loop control mode is selected: Set [Pr. PE03] to "1 _ _ _".
When a linear servo motor or a direct drive motor is used: Set [Pr. PL04] to "1 _ _ _".
*5 In some controller communication status, the alarm factor may not be removed.
*6 This alarm occurs only in the J3 compatibility mode.
*7 Reset alarms while all the safety observation functions have stopped.
8D
CC-Link IE communication error
8D.1
CC-Link IE communication error 1
SD
8D.2
CC-Link IE communication error 2
SD
8D.3
Master station setting error 1
DB
8D.5
Master station setting error 2
DB
8D.6
CC-Link IE communication error 3
SD
8D.7
CC-Link IE communication error 4
SD
8D.8
CC-Link IE communication error 5
SD
8D.9
Synchronization error 1
SD
8D.A
Synchronization error 2
SD
8E
USB communication error/Serial
communication error/Modbus RTU
communication error
8E.1
USB communication receive error/serial
communication receive error
SD
8E.2
USB communication checksum error/
serial communication checksum error
SD
8E.3
USB communication character error/
serial communication character error
SD
8E.4
USB communication command error/
serial communication command error
SD
8E.5
USB communication data number error/
serial communication data number error
SD
8E.6
Modbus RTU communication receive
error
SD
8E.7
Modbus RTU communication message
frame error
SD
8E.8
Modbus RTU communication CRC error
SD
88888
Watchdog
8888._
Watchdog
DB
series
Servo motor
HG-KR
HG-KR053/HG-KR13/HG-KR23/HG-KR43
HG-MR
HG-MR053/HG-MR13/HG-MR23/HG-MR43
HG-SR
HG-SR51/HG-SR52
HG-AK
HG-AK0136/HG-AK0236/HG-AK0336
Alarm
Details
Stop
method