7 CHARACTERISTICS
7.3 Dynamic brake characteristics
59
7
Dynamic brake time constant
The following shows dynamic brake time constant
τ
.
Permissible load to motor inertia when the dynamic brake is used
Use the dynamic brake under the load to motor inertia ratio indicated in the following table. If the ratio is higher than this value,
the dynamic brake may burn. If there is a possibility that the ratio may exceed the value, contact your local sales office.
The values of the permissible load to motor inertia ratio in the table are the values at the maximum rotation speed of the servo
motor.
Servo motor
Load to motor inertia ratio
HG-JR110K24W0C
10
HG-JR150K24W0C
10
HG-JR180K24W0C
10
HG-JR200K24W0C
10
HG-JR220K24W0C
10
0
20
40
60
80
100
120
140
160
180
200
0
500
1000
1500
2000
2500
3000
HG-JR110K24W0C
HG-JR150K24W0C
HG-JR220K24W0C
HG-JR200K24W0C
HG-JR180K24W0C
Speed [r/min]
Time constant
τ