General-Purpose AC Servo

 

Battery for Junction Battery Cable 

Model 

MR-BAT6V1BJ 

Installation Guide 

D

 

CAUTION

 

This product is only for MR J4 servo amplifiers. This is not available with other servo 

amplifiers. 

To avoid deleting data, replace an MR-BAT6V1BJ according to procedures written in this 

installation guide. 

This product is compatible only with HG series servo motors. 

When replacing an MR-BAT6V1BJ, use new one. 

Check that the new MR-BAT6V1BJ is within its estimated life. 

The battery built in MR-BAT6V1BJ cannot be replaced. Do not disassemble the MR-

BAT6V1BJ. Otherwise, it may cause a malfunction. 

 

1. INTRODUCTION 

This product is only for MR J4 servo amplifiers. This is not available with other servo amplifiers. 

Using MR-BAT6V1BJ battery for junction battery cable enables you to keep the absolute position data recorded in 

the encoder even if the servo amplifier is removed from machine. 

 

2. SPECIFICATIONS 

Item Description 

System 

 

Electronic battery backup type 

Model  

MR-BAT6V1BJ 

Battery pack 

 

2CR17335A (primary lithium battery) 

Nominal voltage 

[V] 

Nominal capacity 

[mAh] 

1650 

(Note) Battery life 

 

5 years from date of manufacture 

Maximum number of connectable axes 

 

 

Note. 

Quality of the batteries degrades by the storage condition. The battery life is 5 years from the production date regardless of the 
connection status. 
Production year and month are indicated in a serial number (SERIAL) on the rating plate. The second digit from left in the number 
indicates the first digit of the year, The third digit from left indicates a month (Oct: X, Nov: Y, Dec.: Z). For November 2013, the serial 
is like, "SERIAL: _ 3Y _ _ _ _ _ _". 

 

3. Parts identification 

Orange: Connector for servo amplifier

Black: Connector for branch cable

Case

 

4. Configuration 

4.1 Mounting 

 

(1)  Wire the product using the MR-BT6VCBL03M junction battery cable as follows. 

 

(2)  After wiring, startup the absolute position detection system. Even if the connector for branch cable 

connection (black) is not connected to the MR-BT6VCBL03M junction battery cable, an alarm will not occur. 

Check that they are connected securely. 

 

(3)  When you transport a servo amplifier and machine apart, disconnect only CN2 and CN4 of the servo 

amplifier. When other connectors or cables are disconnected, the absolute position data will be deleted. 

CN2

CN4

Servo amplifier

MR-J4-A(-RJ)

MR-J4-B(-RJ)

Orange: Connector for servo amplifier

Black: Connector for branch cable

Encoder cable

HG series servo motors

MR-BT6VCBL03M

MR-BAT6V1BJ

 

4.2 How to replace MR-BAT6V1BJ 

 

4.2.1 Preparation 

 

Prepare a new MR-BAT6V1BJ as follows. 

 

Model 

Number and Use 

Remark 

MR-BAT6V1BJ 

1 for replacement 

Battery within two years from the production date. 

 

4.2.2 Procedures 

 

Replace the product as follows regardless of on/off of the control circuit power supply. When it is replaced with 

other procedures, the absolute position data will be erased. 

 

(1)  Remove the connector for branch cable connection 

(black) of the old MR-BAT6V1BJ.

 

MR-BT6VCBL03M

CN4

CN2

Servo amplifier

Old MR-BAT6V1BJ

New MR-BAT6V1BJ

 

 

(2)  Connect the connector for branch cable connection 

(black) of the new MR-BAT6V1BJ.

 

MR-BT6VCBL03M

CN4

CN2

Servo amplifier

Old MR-BAT6V1BJ

New MR-BAT6V1BJ

 

 

 

(3)  Remove the connector for servo amplifier (orange) of 

the old MR-BAT6V1BJ. 

When the control circuit power supply is on, performing

(3) without [AL. 9F.2 Battery degradation warning] will

trigger [AL. 9F.2].

 

MR-BT6VCBL03M

CN4

CN2

Servo amplifier

Old MR-BAT6V1BJ

New MR-BAT6V1BJ

 

 

 

(4)  Remove the old MR-BAT6V1BJ from servo amplifier 

and mount the new MR-BAT6V1BJ. 

When the control circuit power supply is on, [AL. 9F.2]

will occur after (3).

 

MR-BT6VCBL03M

CN4

CN2

Servo amplifier

New MR-BAT6V1BJ

Old MR-BAT6V1BJ

 

 

 

(5)  Mount the connector for servo amplifier (orange) of the 

new MR-BAT6V1BJ. 

When the control circuit power supply is on, [AL. 9F.2] 

will be canceled.

 

MR-BT6VCBL03M

CN4

CN2

Servo amplifier

New MR-BAT6V1BJ

 

 

4.3 Troubleshooting 

 

The following shows warnings and alarms which are triggered with power on of the servo amplifier when the wiring 

of the battery for the junction battery cable is incorrect. When you do not solve a problem even after doing the 

following actions, refer to troubleshooting of each servo amplifier instruction manual. 

 

Display Name 

Cause 

Action 

AL. 9F 

Battery warning 

1. MR-BAT6V1BJ is not connected to CN4. 

Connect MR-BAT6V1BJ to CN4. 

 

 

2. Battery voltage dropped. 

Replace MR-BAT6V1BJ. 

AL. 92 

Battery cable 
disconnection 
warning 

1. Battery voltage dropped. 

Replace MR-BAT6V1BJ. 

 

2. MR-BAT6V1BJ is not connected to CN4 or 

MR-BT6VCBL03M. 

Connect MR-BAT6V1BJ to CN4 and MR-
BT6VCBL03M. 

AL. 25 

Absolute position 
erased 

1. The power was turned off while MR-

BAT6V1BJ was not connected to CN4 or 
MR-BT6VCBL03M. 

Connect MR-BAT6V1BJ to CN4 and MR-
BT6VCBL03M. 

2. The servo amplifier was removed from 

machine while MR-BAT6V1BJ was not 
connected to MR-BT6VCBL03M. 

Connect MR-BAT6V1BJ to MR-
BT6VCBL03M. 

3. MR-BT6VCBL03M was not connected to 

an encoder cable. 

Connect the MR-BT6VCBL03M to the 
encoder cable. 

 

4.4 Precautions for using 

 

(1)  The connector for servo amplifier connection (orange) has a lock release lever. When removing the 

connector, pull out the connector while pressing the lock release lever. 

 

(2)  The connector servo amplifier connection (orange) and the connector for branch cable connection (black) 

are different in color and shape due to different output voltage. Incorrect connection can cause the machine 

to be damaged. 

 

(3)  When a cable is cut or shorted due to load or being caught, the built-in battery will have high temperature. 

Do not disassemble the MR-BAT6V1BJ to prevent getting burnt. 

 

5. DIMENSIONS 

 

[Unit: mm] 

34.8

69.3

38.5

Rating plate

 

Mass: 66 [g] 

6. Battery transportation 

When only lithium metal batteries are transported, attachment of a handling label to each package, submission of 

the Shipper's Declaration for Dangerous Goods, and a 1.2 m drop test will be required. When the batteries are 

transported with mounted on products, the regulations about package, etc. will not be required. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MITSUBISHI ELECTRIC CORPORATION 

HEAD OFFICE: TOKYO BLDG MARUNOUCHI TOKYO 100-8310 

  

IB(NA)0300213ENG-D(1702)MEE

 

 

This guide uses recycled paper. 

Printed in Japan 

Specifications are subject to change without notice. 

 