160
6 OPTIONS AND PERIPHERAL EQUIPMENT
6.2 Regenerative option
6.2
Regenerative option
Combination and regenerative power
The power values in the table are resistor-generated powers and not rated powers.
200 V class
*1 Install a cooling fan when using this regenerative option.
*2 Depending on the operating conditions, a cooling fan must be installed.
Page 168 Connection of regenerative option
Servo amplifier
Regenerative power [W]
Built-in
regenerative
resistor
MR-
RB032
[40
Ω
]
MR-
RB12
[40
Ω
]
MR-
RB14
[26
Ω
]
MR-
RB30
[13
Ω
]
MR-
RB3N
[9
Ω
]
MR-
RB31
[6.7
Ω
]
MR-
RB34
[26
Ω
]
MR-
RB50
[13
Ω
]
MR-
RB5N
[9
Ω
]
MR-
RB51
[6.7
Ω
]
MR-J5-10_
30
MR-J5-20_
10
30
100
MR-J5-40_
10
30
100
MR-J5-60_
10
20
100
MR-J5-70_
30
100
300
MR-J5-100_
30
100
300
MR-J5-200_
100
300
500
MR-J5-350_
100
300
500
MR-J5-500_
130
300
500
MR-J5-700_
170
MR-J5W2-22G_
20
100
MR-J5W2-44G_
20
100
MR-J5W2-77G_
100
300
MR-J5W2-1010G_
100
300
MR-J5W3-222G_
30
100
300
MR-J5W3-444G_
30
100
300
Summary of Contents for Melservo-J5 MR-J5 Series