3 SIGNALS AND WIRING
3.8 Grounding
101
3
3.8
Grounding
The servo amplifier supplies power to the servo motor by switching on and off a power transistor. Depending on the wiring and
ground wire routing, the servo amplifier may be affected by the switching noise (due to di/dt and dv/dt) of the transistor. To
prevent such a fault, refer to the following diagram and ground it.
For information on how to comply with the EMC Directive, refer to "EMC Installation Guidelines".
V
U
U
E
V
W
W
CN2
L11
L1
L2
L3
L21
MC
MCCB
M
Cabinet
Servo amplifier
Servo motor
Line filter
Encoder
Power supply
Outer box
Protective earth (PE)
To ground the servo motor, connect the
grounding lead wire to the servo amplifier, then
connect the wire from the servo amplifier to the
ground via the protective earth (PE) terminal of
the cabinet. Do not connect the wire directly to
the protective earth (PE) terminal of the cabinet.
Summary of Contents for Melservo-J5 MR-J5 Series
Page 2: ......
Page 441: ...12 USING A FULLY CLOSED LOOP SYSTEM 12 7 Absolute position detection system 439 12 MEMO ...
Page 445: ......