6 OPTIONS AND PERIPHERAL EQUIPMENT
6.10 Molded-case circuit breakers, fuses, magnetic contactors
Driving on/off of main circuit power supply with DC power supply [G] [A]
Use the magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of
contacts) of 80 ms or less.
Driving on/off of main circuit power supply with DC power supply [WG]
Use the magnetic contactor with an operation delay time (interval between current being applied to the coil until closure of
contacts) of 80 ms or less.
■
MR-J5W2-_G_
■
MR-J5W3-_G_
Servo amplifier
Magnetic contactor
MR-J5-10_ to MR-J5-100_
SD-T12
MR-J5-200_/MR-J5-350_
SD-T21
MR-J5-500_
SD-T35
MR-J5-700_
SD-T50
Total output of rotary servo motors
Total continuous thrust of linear
servo motors
Total output of direct drive motors
Magnetic
contactor
300 W or less
SD-T11
From over 300 W to 600 W
150 N or less
100 W or less
From over 600 W to 1 kW
From over 150 N to 300 N
From over 100 W to 252 W
From over 1 kW to 2 kW
From over 300 N to 720 N
From over 252 W to 838 W
SD-T21
Total output of rotary servo motors
Total continuous thrust of linear
servo motors
Total output of direct drive motors
Magnetic
contactor
450 W or less
150 N or less
SD-T11
From over 450 W to 800 W
From over 150 N to 300 N
252 W or less
From over 800 W to 1.5 kW
From over 300 N to 450 N
From over 252 W to 378 W
SD-T21