11 USING A DIRECT DRIVE MOTOR
11.2 Startup [G] [WG]
365
11
11.2
Startup [G] [WG]
When using a direct drive motor, set [Pr. PA01.1 Operation mode selection] to "6" (Direct drive motor control mode).
After power-on, the Z-phase mark of the direct drive motor manufactured by Mitsubishi Electric must pass the connector area
once. In a system which prevents the direct drive motor from making a full rotation or more, install the direct drive motor in a
position where the Z-phase mark can pass over the connector area.
Startup procedure
Start up the direct drive servo system with the following procedure.
No
Yes
Installation and wiring
Absolute position detection system
Incremental system
Absolute position
detection system?
Set [Pr. PA03.0 Absolute position detection
system selection] to "1".
Cancel [AL. 025 Absolute position erased].
*4
Can the Z-phase pulse of the
direct drive motor manufactured
by Mitsubishi Electric be
turned on manually?
Perform the magnetic pole detection.
*1
Turn on the Z-phase pulse of the direct
drive motor by using the JOG operation.
*1, *2
Manually turn on the Z-phase pulse of the direct
drive motor manufactured by Mitsubishi Electric.
Change the setting to disable the magnetic
pole detection.
Cycle the power of the servo amplifier or
reset the software.
*2
Positioning operation check in test operation mode
*1
Positioning operation check with the controller (Refer to the manual of the controller used.)
Homing operation
Positioning operation
Summary of Contents for Melservo-J5 MR-J5 Series
Page 2: ......
Page 441: ...12 USING A FULLY CLOSED LOOP SYSTEM 12 7 Absolute position detection system 439 12 MEMO ...
Page 445: ......