5. PARAMETERS
5 - 1
5. PARAMETERS
CAUTION
Never make a drastic adjustment or change to the parameter values as doing so
will make the operation unstable.
If fixed values are written in the digits of a parameter, do not change these values.
Do not change parameters for manufacturer setting.
Do not set a value other than the described values to each parameter.
5.1 Parameter list
POINT
To enable a parameter whose symbol is preceded by *, turn off the power for 1 s
or more after setting and turn it on again. However, the time will be longer
depending on a setting value of [Pr. PF25 SEMI-F47 function - Instantaneous
power failure detection time (instantaneous power failure tough drive - detection
time)] when "SEMI-F47 function selection (instantaneous power failure tough
drive selection)" is enabled in [Pr. PA20].
The symbols in the control mode column mean as follows.
P: Position control mode
S: Speed control mode
T: Torque control mode
5.1.1 Basic setting parameters ([Pr. PA_ _ ])
Control mode
No.
Symbol
Name
Initial
value
Unit
P
S
T
PA01
*STY
Operation mode
1000h
PA02
*REG
Regenerative option
0000h
PA03
For manufacturer setting
0000h
PA04
*AOP1 Function selection A-1
2000h
PA05
*FBP
Number of command input pulses per revolution
10000
PA06
CMX
Electronic gear numerator (command pulse multiplication numerator)
1
PA07
CDV
Electronic gear denominator (command pulse multiplication denominator)
1
PA08
ATU
Auto tuning mode
0001h
PA09
RSP
Auto tuning response
16
PA10
INP
In-position range
100
[pulse]
PA11
TLP
Forward rotation torque limit
100.0
[%]
PA12
TLN
Reverse rotation torque limit
100.0
[%]
PA13
*PLSS
Command pulse input form
0100h
PA14
*POL
Rotation direction selection
0
PA15
*ENR
Encoder output pulses
4000
[pulse/rev]
PA16
*ENR2 Encoder output pulses 2
1
PA17
For manufacturer setting
0000h
PA18
0000h
PA19
*BLK
Parameter writing inhibit
00AAh
PA20
*TDS
Tough drive setting
0000h
PA21
*AOP3 Function selection A-3
0001h
PA22
For manufacturer setting
0000h
PA23
DRAT
Drive recorder arbitrary alarm trigger setting
0000h
PA24
AOP4
Function selection A-4
0000h
PA25
OTHOV One-touch tuning - Overshoot permissible level
0
[%]
PA26
*AOP5 Function selection A-5
0000h
PA27
For manufacturer setting
0000h
PA28
0000h
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...