5. PARAMETERS
5 - 14
Control mode
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
P
S
T
Select servo motor rotation direction relative to the input pulse train.
0
Servo motor rotation direction
PA14
*POL
Rotation
direction
selection
Setting
value
When forward rotation
pulse is input
When reverse rotation
pulse is input
0
CCW
CW
1
CW
CCW
The following shows the servo motor rotation directions.
Forward rotation (CCW)
Reverse rotation (CW)
Setting range: 0, 1
PA15
*ENR
Encoder
output pulses
Set the encoder output pulses from the servo amplifier by using the number of
output pulses per revolution, dividing ratio, or electronic gear ratio. (after
multiplication by 4)
To set a numerator of the electronic gear, select "A-phase/B-phase pulse electronic
gear setting (_ _ 3 _)" of "Encoder output pulse setting selection" in [Pr. PC19].
The maximum output frequency is 4.6 Mpulses/s. Set the parameter within this
range.
Setting range: 1 to 4194304
4000
[pulse/
rev]
PA16
*ENR2
Encoder
output pulses
2
Set a denominator of the electronic gear for the A/B-phase pulse output.
To set a denominator of the electronic gear, select "A-phase/B-phase pulse
electronic gear setting (_ _ 3 _)" of "Encoder output pulse setting selection" in [Pr.
PC19].
Setting range: 1 to 4194304
1
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...