5. PARAMETERS
5 - 24
Control mode
No./
symbol/name
Setting
digit
Function
Initial
value
[unit]
P
S
T
Set the command notch filter.
_ _ x x Command notch filter setting frequency selection
Refer to table 5.6 for the relation of setting values to frequency.
00h
PB45
CNHF
Command
notch filter
_ x _ _ Notch depth selection
Refer to table 5.7 for details.
0h
x _ _ _ For manufacturer setting
0h
Table 5.6 Command notch filter setting frequency selection
Setting
value
Frequency
[Hz]
Setting
value
Frequency
[Hz]
Setting
value
Frequency
[Hz]
00
Disabled
20
70
40
17.6
01
2250
21
66
41
16.5
02
1125
22
62
42
15.6
03
750
23
59
43
14.8
04
562
24
56
44
14.1
05
450
25
53
45
13.4
06
375
26
51
46
12.8
07
321
27
48
47
12.2
08
281
28
46
48
11.7
09
250
29
45
49
11.3
0A
225
2A
43
4A
10.8
0B
204
2B
41
4B
10.4
0C
187
2C
40
4C
10
0D
173
2D
38
4D
9.7
0E
160
2E
37
4E
9.4
0F
150
2F
36
4F
9.1
10
140
30
35.2
50
8.8
11
132
31
33.1
51
8.3
12
125
32
31.3
52
7.8
13
118
33
29.6
53
7.4
14
112
34
28.1
54
7.0
15
107
35
26.8
55
6.7
16
102
36
25.6
56
6.4
17
97
37
24.5
57
6.1
18
93
38
23.4
58
5.9
19
90
39
22.5
59
5.6
1A
86
3A
21.6
5A
5.4
1B
83
3B
20.8
5B
5.2
1C
80
3C
20.1
5C
5.0
1D
77
3D
19.4
5D
4.9
1E
75
3E
18.8
5E
4.7
1F
72
3F
18.2
5F
4.5
Table 5.7 Notch depth selection
Setting
value
Depth [dB]
Setting
value
Depth [dB]
0
-40.0
8
-6.0
1
-24.1
9
-5.0
2
-18.1
A
-4.1
3
-14.5
B
-3.3
4
-12.0
C
-2.5
5
-10.1
D
-1.8
6
-8.5
E
-1.2
7
-7.2
F
-0.6
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...