7. SPECIAL ADJUSTMENT FUNCTIONS
7 - 16
(2) Switchable gain parameter
Before switching
After switching
Loop gain
Parameter Symbol
Name
Parameter
Symbol
Name
Load to motor inertia ratio
PB06
GD2
Load to motor inertia ratio
PB29
GD2B
Gain switching
Load to motor inertia ratio
Model loop gain
PB07
PG1
Model loop gain
PB60
PG1B
Gain switching
Model loop gain
Position loop gain
PB08
PG2
Position loop gain
PB30
PG2B
Gain switching
Position loop gain
Speed loop gain
PB09
VG2
Speed loop gain
PB31
VG2B
Gain switching
Speed loop gain
Speed integral
compensation
PB10
VIC
Speed integral
compensation
PB32
VICB
Gain switching
Speed integral
compensation
Vibration suppression
control 1
Used to set the value of the
after-changing vibration
suppression control
vibration frequency setting.
PB19
VRF11 Vibration suppression
control 1
Used to set the value of the
after-changing vibration
suppression control
vibration frequency setting.
PB33
VRF11B Vibration suppression
control 1 - Vibration
frequency after gain
switching
Vibration suppression
control 1 - Resonance
frequency
PB20
VRF12 Vibration suppression
control 1 - Resonance
frequency
PB34
VRF12B Vibration suppression
control 1 - Resonance
frequency after gain
switching
Vibration suppression
control 1 - Vibration
frequency damping
PB21
VRF13 Vibration suppression
control 1 - Vibration
frequency damping
PB35
VRF13B Vibration suppression
control 1 - Vibration
frequency damping after
gain switching
Vibration suppression
control 1 - Resonance
frequency damping
PB22
VRF14 Vibration suppression
control 1 - Resonance
frequency damping
PB36
VRF14B Vibration suppression
control 1 - Resonance
frequency damping after
gain switching
Vibration suppression
control 2 - Vibration
frequency
PB52
VRF21 Vibration suppression
control 2 - Vibration
frequency
PB56
VRF21B Vibration suppression
control 2 - Vibration
frequency after gain
switching
Vibration suppression
control 2 - Resonance
frequency
PB53
VRF22 Vibration suppression
control 2 - Resonance
frequency
PB57
VRF22B Vibration suppression
control 2 - Resonance
frequency after gain
switching
Vibration suppression
control 2 - Vibration
frequency damping
PB54
VRF23 Vibration suppression
control 2 - Vibration
frequency damping
PB58
VRF23B Vibration suppression
control 2 - Vibration
frequency damping after
gain switching
Vibration suppression
control 2 - Resonance
frequency damping
PB55
VRF24 Vibration suppression
control 2 - Resonance
frequency damping
PB59
VRF24B Vibration suppression
control 2 - Resonance
frequency damping after
gain switching
(a) [Pr. PB06] to [Pr. PB10]
These parameters are the same as in ordinary manual adjustment. Gain switching allows the values
of load to motor inertia ratio, position loop gain, speed loop gain, and speed integral compensation to
be switched.
(b) [Pr.PB19] to [Pr.PB22]/[Pr.PB52] to [Pr.PB55]
These parameters are the same as in ordinary manual adjustment. You can switch the vibration
frequency, resonance frequency, vibration frequency damping, and resonance frequency damping
by switching gain during motor stop.
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...