8. TROUBLESHOOTING
8 - 7
Alarm No.: 12
Name: Memory error 1 (RAM)
Alarm content
A part (RAM) in the servo amplifier is failure.
Display Detail name
Cause
Check method
Check result
Action
12.1 RAM error 1
(1) A part in the servo
amplifier is failure.
It is repeatable.
Replace the servo
amplifier.
Disconnect the cables
except the power supply,
and then check the
repeatability.
It is not repeatable.
Check (2).
(2) Something near the
device caused it.
Check the power supply
for noise.
It has a failure.
Take countermeasures
against its cause.
12.2 RAM error 2
Check it with the check method for [AL. 12.1].
12.4 RAM error 4
12.5 RAM error 5
Alarm No.: 13
Name: Clock error
Alarm content
A part in the servo amplifier is failure.
Display Detail name
Cause
Check method
Check result
Action
13.1 Clock error 1
(1) A part in the servo
amplifier is failure.
It is repeatable.
Replace the servo
amplifier.
Disconnect the cables
except the power supply,
and then check the
repeatability.
It is not repeatable.
Check (2).
(2) Something near the
device caused it.
Check the power supply
for noise.
Check if the connector is
shorted.
It has a failure.
Take countermeasures
against its cause.
13.2 Clock error 2
Check it with the check method for [AL. 13.1].
Alarm No.: 14
Name: Control process error
Alarm content
The process did not complete within the specified time.
Display Detail name
Cause
Check method
Check result
Action
14.1
(1)
It is incorrect.
Set it correctly.
Control process
error 1
The parameter setting is
incorrect.
Check if the parameter
setting is incorrect.
It is correct.
Check (2).
(2) Something near the
device caused it.
It has a failure.
Take countermeasures
against its cause.
Check the power supply
for noise. Check if the
connector is shorted.
It has no failure.
Check (3).
(3) The servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then check
the repeatability.
It is not repeatable.
Replace the servo
amplifier.
14.2
(1)
It is incorrect.
Set it correctly.
Control process
error 2
The parameter setting is
incorrect.
Check if the parameter
setting is incorrect.
It is correct.
Check (2).
(2) Something near the
device caused it.
It has a failure.
Take countermeasures
against its cause.
Check the power supply
for noise. Check if the
connector is shorted.
It has no failure.
Check (3).
(3) The servo amplifier is
malfunctioning.
Replace the servo
amplifier, and then check
the repeatability.
It is not repeatable.
Replace the servo
amplifier.
14.3 Control process
error 3
Check it with the check method for [AL. 14.1].
14.4 Control process
error 4
14.5 Control process
error 5
14.6 Control process
error 6
14.7 Control process
error 7
14.8 Control process
error 8
14.9 Control process
error 9
14.A Control process
error 10
Summary of Contents for MELSERVO-JE MR-JE-100A
Page 23: ...1 FUNCTIONS AND CONFIGURATION 1 12 MEMO ...
Page 29: ...2 INSTALLATION 2 6 MEMO ...
Page 91: ...3 SIGNALS AND WIRING 3 62 MEMO ...
Page 171: ...5 PARAMETERS 5 44 MEMO ...
Page 195: ...6 NORMAL GAIN ADJUSTMENT 6 24 MEMO ...
Page 221: ...7 SPECIAL ADJUSTMENT FUNCTIONS 7 26 MEMO ...
Page 249: ...8 TROUBLESHOOTING 8 28 MEMO ...
Page 255: ...9 DIMENSIONS 9 6 MEMO ...
Page 263: ...10 CHARACTERISTICS 10 8 MEMO ...
Page 293: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 30 MEMO ...