For the symptoms listed below, refer to the remedies listed right.
The unit blows out warm air because dehumidifi ed air passes through
the reheater (there is no cooler function). This is not a malfunction.
P3
The unit blows warm air
Check to see if the temperature/humidity is low.
Low room temperature/humidity reduces dehumidifying effectiveness.
This is not a malfunction.
P3
Water does not collect in
the water tank (minimal
dehumidifying results)
Check to see if the power cord is correctly plugged.
Plug the power cord properly into the power socket.
→
P10
Check to see if anything is blocking the air intake or outlet.
Remove the obstruction.
→
P5
Is operation being performed with the unit set to EASY DEHUMIDIFYING
or AUTO?
The unit is automatically switching dehumidifying, blowing, and stopping.
→
P12~13
Is operation being performed with the unit set to Bathroom Mildew Guard?
Operation stops automatically if the humidity falls. Operation stops
after a minimum of 4 hours.
→
P15
Check to see if the pre-fi lter is clogged.
Clean according to the maintenance procedures.
→
P22
Is operation being performed with the unit set to INTELLIGENT LAUNDRY?
If the room temperature is approximately 5°C or less, operation stops after
approximately 1 hour. If the room temperature is low, it becomes diffi cult for
water to evaporate from clothes because the humidity does not change.
→
P12~13
Is operation being performed with the unit set to DEO-DRY?
This operation is designed to end after approximately 1 hour.
→
P18
Check to see if the water tank is full.
Empty the water tank and return it to its original position.
→
P20
Check to see if the water tank is inserted properly.
Adjust the position of the water tank.
→
P10
Check to see if the unit is in defrosting mode. The unit activates
defrosting mode when the room temperature drops below 15°C. The
dehumidifi er and blower functions stop during defrosting.
P3
Is operation being performed with the unit set to DEO-DRY?
“
” is displayed during compressor operation.
→
P18
The unit does not operate (No
air comes out and the louvre
does not swing)
The unit stops
Stops after
a short time
Lights
Indicates
Is the unit set to drying inside mode?
This function activates automatically after ending operations.
P19
The unit continues to operate
even though it is turned off
Check to see if the room is not too large.
Check to see if the exits to the room are open.
Refrain from opening doors/windows during operation.
→
Check to see if steam producing appliances such as kerosene heaters are on
in the vicinity.
The humidity level does not
drop to the set level easily
Hygrometer readings differ from place to place even if in the same room.
Use the unit humidity reading as an estimate.
P3
The hygrometer reading on
the unit differs from other
hygrometers in the room
Symptom
Cause/Remedy
Troubleshooting
The residue is from debris in the air.
Clean according to the maintenance procedures.
→
P22
There is black residue on the
inside of the water tank and
lid.
The residue is from fi nal product testing at the factory. It is not a result of a
malfunction.
The water tank contains liquid
or white water residue
Press the Swing louvre switch again.
P16
The louvre does not move as
set