13. OPTIONS AND AUXILIARY EQUIPMENT
13.1.3 Power regeneration converter
When using the power regeneration converter, set "01
" in parameter No.0.
(1) Selection
The converters can continuously return 75% of the nominal regenerative power. They are applied to
the servo amplifiers of the MR-J2S-500A to MR-J2S-22KA.
Power
regeneration
converter
Nominal
Regenerative
Power (kW)
Servo Amplifier
FR-RC-15
15
MR-J2S-500A
MR-J2S-700A
FR-RC-30
30
MR-J2S-11KA
MR-J2S-15KA
FR-RC-55K
55
MR-J2S-22KA
0
50
75
100
150
500
300
200
100
50
30
20
Cont
in
uo
us
ene
rg
iza
tion t
im
e [
sec
]
Nominal regenerative power (%)