1 - 4
1. FUNCTIONS AND CONFIGURATION
(2) 400V class
Servo amplifier
MR-J3- -RJ006
Item
60B4 100B4 200B4 350B4 500B4 700B4 11KB4 15KB4 22KB4
Voltage/frequency
3-phase 380 to 480VAC, 50/60Hz
Permissible voltage fluctuation
3-phase 323 to 528VAC
Permissible frequency
fluctuation
Within 5%
Power supply capacity
Refer to section 10.2
P
ower s
uppl
y
Inrush current
Refer to section 10.5
Voltage/frequency
1-phase 380 to 480VAC, 50/60Hz
Permissible
voltage
fluctuation
1-phase 323 to 528VAC
Permissible
frequency
fluctuation
Within 5%
Input
30W
45W
Control circuit
power supply
Inrush current
Refer to section 10.5
Voltage 24VDC
10%
Interface power
supply
Power supply
capacity
(Note 1) 150mA or more
Serial interface
Mitsubishi high-speed serial communication
Input
signal
ABZ-phase differential input signal
Load side
encoder
interface
Pulse
train
inter-
face
Minimum
phase
differential
200ns
Control System
Sine-wave PWM control, current control system
Dynamic
brake
Built-in
External
option
Protective functions
Overcurrent shut-off, regenerative overvoltage shut-off, overload shut-off (electronic thermal relay),
servo motor overheat protection, encoder error protection, regenerative brake error protection,
undervoltage, instantaneous power failure protection, overspeed protection, excessive error
protection
Structure
Self-cooled, open
(IP00)
Force-cooling, open (IP00)
[ ]
(Note 2) 0 to 55 (non-freezing)
In
operation
[ ]
(Note 2) 32 to 131 (non-freezing)
[ ]
20 to 65 (non-freezing)
Ambient
temperature
In storage
[ ]
4 to 149 (non-freezing)
In operation
Ambient
humidity
In storage
90%RH or less (non-condensing)
Ambient
Indoors (no direct sunlight)
Free from corrosive gas, flammable gas, oil mist, dust and dirt
Altitude
Max. 1000m above sea level
E
nv
ironm
ent
Vibration 5.9
[m/s
2
] or less
[kg]
1.7 1.7 2.1 4.6 4.6 6.2 18 18 19
Mass
[lb]
3.75 3.75 4.63 10.1 10.1 13.7 39.7 39.7 41.9
Note 1. 150mA is the value applicable when all I/O signals are used. The current capacity can be decreased by reducing the number of
I/O points.
2. When closely mounting the servo amplifiers of 3.5kW or less, operate them at the ambient temperatures of 0 to 45 (32 to
113 ) or at 75% or a smaller effective load ratio.
Summary of Contents for MR-J3-B-RJ006
Page 15: ...A 14 MEMO ...
Page 19: ...4 MEMO ...
Page 65: ...2 18 2 SIGNALS AND WIRING MEMO ...
Page 119: ...4 22 4 OPERATION AND FUNCTIONS MEMO ...
Page 145: ...6 6 6 TROUBLESHOOTING MEMO ...
Page 155: ...7 10 7 OUTLINE DRAWINGS MEMO ...
Page 165: ...SH NA 030056 C ...