3 - 9
3. LOAD SIDE ENCODER
(c) For ST741A or ST743A
1) Cable structure
Prepare a cable based on the following structure diagram.
CN2L
2)
1)
3)
Servo amplifier
Personal computer
Software for
signal adjustment
Conversion unit
For the signal adjustment and confirmation, connect the following equipments. (Note 2)
Linear encoder
ST741A
Load side encoder cable
Head cable
Cable
Load side encoder cable
Head cable
When using an
optional cable
1) Options manufactured by Mitutoyo Corporation (This should be prepared by
the customer.) (Note 1)
Part No.06ACF117A: 5m
Part No.06ACF117B: 10m
When producing a
load side encoder
cable
2) Connector set MR-J3CN2
(Option manufactured by
Mitsubishi Electric
Corporation)
(Refer to section 3.4.)
3) Junction connector (This should be
prepared by the customer.)
D-SUB (female) 15 Pin shell: HDAB-15S’
Plug case: HDA-CTH
(manufactured by HIROSE ELECTRIC
CO., LTD)
Accessories for linear encoder
Cable length: 1m
Note 1. For details, contact with Mitutoyo Corporation .
2. When mounting ST741A ST743A, a personal computer (with RS-232C port) for the signal adjustment and confirmation, and a
software and conversion unit for signal adjustment are required. For details, contact with Mitutoyo Corporation.
Summary of Contents for MR-J3-B-RJ006
Page 15: ...A 14 MEMO ...
Page 19: ...4 MEMO ...
Page 65: ...2 18 2 SIGNALS AND WIRING MEMO ...
Page 119: ...4 22 4 OPERATION AND FUNCTIONS MEMO ...
Page 145: ...6 6 6 TROUBLESHOOTING MEMO ...
Page 155: ...7 10 7 OUTLINE DRAWINGS MEMO ...
Page 165: ...SH NA 030056 C ...