5. PARAMETERS
5 - 17
No.
Symbol
Name and function
Initial
value
[unit]
Setting
range
PA17
**MSR
Servo motor series setting
When you use a linear servo motor, select its model from [Pr. PA17] and [Pr. PA18]. Set this
and [Pr. PA18] at a time.
Refer to the following table for settings.
0000h Refer
to
the
"Name
and
function"
column.
Linear servo motor
series
Linear servo motor
(primary side)
Parameter
[Pr. PA17] setting [Pr. PA18] setting
LM-H3
LM-H3P2A-07P-BSS0
00BBh
2101h
LM-H3P3A-12P-CSS0
3101h
LM-H3P3B-24P-CSS0
3201h
LM-H3P3C-36P-CSS0
3301h
LM-H3P3D-48P-CSS0
3401h
LM-H3P7A-24P-ASS0
7101h
LM-H3P7B-48P-ASS0
7201h
LM-H3P7C-72P-ASS0
7301h
LM-H3P7D-96P-ASS0
7401h
LM-U2
LM-U2PAB-05M-0SS0
00B4h
A201h
LM-U2PAD-10M-0SS0
A401h
LM-U2PAF-15M-0SS0
A601h
LM-U2PBB-07M-1SS0
B201h
LM-U2PBD-15M-1SS0
B401h
LM-U2PBF-22M-1SS0
2601h
LM-U2P2B-40M-2SS0
2201h
LM-U2P2C-60M-2SS0
2301h
LM-U2P2D-80M-2SS0
2401h
LM-F
LM-FP2B-06M-1SS0
(natural cooling)
00B2h
2201h
LM-FP2D-12M-1SS0
(natural cooling)
2401h
LM-FP2F-18M-1SS0
(natural cooling)
2601h
LM-FP4B-12M-1SS0
(natural cooling)
4201h
LM-FP4D-24M-1SS0
(natural cooling)
4401h
LM-FP4F-36M-1SS0
(natural cooling)
4601h
LM-FP4H-48M-1SS0
(natural cooling)
4801h
LM-FP5H-60M-1SS0
(natural cooling)
5801h
LM-FP2B-06M-1SS0
(liquid cooling)
2202h
LM-FP2D-12M-1SS0
(liquid cooling)
2402h
LM-FP2F-18M-1SS0
(liquid cooling)
2602h
LM-FP4B-12M-1SS0
(liquid cooling)
4202h
LM-FP4D-24M-1SS0
(liquid cooling)
4402h
LM-FP4F-36M-1SS0
(liquid cooling)
4602h
LM-FP4H-48M-1SS0
(liquid cooling)
4802h
LM-FP5H-60M-1SS0
(liquid cooling)
5802h
Summary of Contents for MR-J4-100B(-RJ)
Page 17: ...8 MEMO ...
Page 143: ...4 STARTUP 4 20 MEMO ...
Page 199: ...5 PARAMETERS 5 56 MEMO ...
Page 227: ...6 NORMAL GAIN ADJUSTMENT 6 28 MEMO ...
Page 281: ...8 TROUBLESHOOTING 8 16 MEMO ...
Page 303: ...9 DIMENSIONS 9 22 MEMO ...
Page 319: ...10 CHARACTERISTICS 10 16 MEMO ...
Page 429: ...11 OPTIONS AND PERIPHERAL EQUIPMENT 11 110 MEMO ...
Page 435: ...12 ABSOLUTE POSITION DETECTION SYSTEM 12 6 MEMO ...
Page 483: ...14 USING A LINEAR SERVO MOTOR 14 34 MEMO ...
Page 531: ...16 FULLY CLOSED LOOP SYSTEM 16 26 MEMO ...
Page 613: ...17 APPLICATION OF FUNCTIONS 17 82 MEMO ...
Page 654: ...APPENDIX App 41 ...